Kurz gefasst

Metaanalyse in der Zeitschrift Journal of Ultrasound, online erschienen am 25.01.2023. Verfasst von Getu Ferenji Tadesse und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, St. Paul's Hospital Millennium Medical College, Addis Ababa, Ethiopia. ofjan2007@gmail.com. Hauptthemen laut MEDLINE: Breast Neoplasms. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The purpose of this study was to assess the diagnostic performance of mammography (MMG) and ultrasound (US) imaging for detecting breast cancer. METHODS: Comprehensive searches of PubMed, Scopus and EMBASE from 2008 to 2021 were performed. A summary receiver operating characteristic curve (SROC) was constructed to summarize the overall test performance of MMG and US. Histopathologic analysis and/or close clinical and imaging follow-up for at least 6 months were used as golden reference. RESULTS: Analysis of the studies revealed that the overall validity estimates of MMG and US in detecting breast cancer were as follows: pooled sensitivity per-patient were 0.82 (95% CI 0.76-0.87) and 0.83 (95% CI 0.71-0.91) respectively, The pooled specificities for detection of breast cancer using MMG, and US were 0.84 (95% CI 0.73-0.92) and 0.84 (95% CI 0.74-0.91) respectively. AUC of MMG, and US were 0.8933 and 0.8310 respectively. Pooled sensitivity and specificity per-lesion was 76% (95% CI 0.62-0.86) and 82% (95% CI 0.66-0.91) for MMG and 94% (95% CI 0.87-0.97) and 84% (95% CI 0.74-0.91) for US. CONCLUSIONS: The meta-analysis found that, US and MMG has similar diagnostic performance in detecting breast cancer on per-patient basis after corrected threshold effect. However, on a per-lesion basis US was found to have a better diagnostic accuracy than MMG.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breast NeoplasmsFemaleHumansMammographyUltrasonography, MammaryUltrasonographySensitivity and Specificity

Stichwörter der Autor:innen

Breast cancerDiagnostic methodsMammographyMeta-analysisUltrasound

Autor:innen und Institutionen

  • Department of Internal Medicine, St. Paul's Hospital Millennium Medical College, Addis Ababa, Ethiopia. ofjan2007@gmail.com.
  • Department of Physics, Faculty of Natural Sciences, Debre Tabor University, Debra Tabor, Ethiopia.
  • Department of Internal Medicine, St. Paul's Hospital Millennium Medical College, Addis Ababa, Ethiopia.

Zitieren

APA

Tadesse, G. F., Tegaw, E. M., & Abdisa, E. K. (2023). Diagnostic performance of mammography and ultrasound in breast cancer: a systematic review and meta-analysis. Journal of Ultrasound, 26(2), 355-367. https://doi.org/10.1007/s40477-022-00755-3

Vancouver

Tadesse GF, Tegaw EM, Abdisa EK. Diagnostic performance of mammography and ultrasound in breast cancer: a systematic review and meta-analysis. Journal of Ultrasound. 2023;26(2):355-367. doi:10.1007/s40477-022-00755-3

BibTeX
@article{Tadesse2023,
  author = {Tadesse, Getu Ferenji and Tegaw, Eyachew Misganew and Abdisa, Ejigu Kebede},
  title = {Diagnostic performance of mammography and ultrasound in breast cancer: a systematic review and meta-analysis},
  journal = {Journal of Ultrasound},
  year = {2023},
  volume = {26},
  number = {2},
  pages = {355--367},
  doi = {10.1007/s40477-022-00755-3}
}
Kostenlos starten →