A systematic review and meta-analysis comparing the diagnostic capability of automated breast ultrasound and contrast-enhanced ultrasound in breast cancer
Frontiers in Oncology · 09.01.2024 · 13
DOI: 10.3389/fonc.2023.1305545 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Frontiers in Oncology, online erschienen am 09.01.2024. Verfasst von Haoyu Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinic Medicine, Chengdu Medical College, Sichuan, China. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
To compare the diagnostic performance of automated breast ultrasound (ABUS) and contrast-enhanced ultrasound (CEUS) in breast cancer.
Methods
Published studies were collected by systematically searching the databases PubMed, Embase, Cochrane Library and Web of Science. The sensitivities, specificities, likelihood ratios and diagnostic odds ratio (DOR) were confirmed. The symmetric receiver operator characteristic curve (SROC) was used to assess the threshold of ABUS and CEUS. Fagan’s nomogram was drawn. Meta-regression and subgroup analyses were applied to search for sources of heterogeneity among the included studies.
Results
A total of 16 studies were included, comprising 4115 participants. The combined sensitivity of ABUS was 0.88 [95% CI (0.73–0.95)], specificity was 0.93 [95% CI (0.82–0.97)], area under the SROC curve (AUC) was 0.96 [95% CI (0.94–0.96)] and DOR was 89. The combined sensitivity of CEUS was 0.88 [95% CI (0.84–0.91)], specificity was 0.76 [95% CI (0.66–0.84)], AUC was 0.89 [95% CI (0.86–0.92)] and DOR was 24. The Deeks’ funnel plot showed no existing publication bias. The prospective design, partial verification bias and blinding contributed to the heterogeneity in specificity, while no sources contributed to the heterogeneity in sensitivity. The post-test probability of ABUS in BC was 75%, and the post-test probability of CEUS in breast cancer was 48%.
Conclusion
Compared with CEUS, ABUS showed higher specificity and DOR for detecting breast cancer. ABUS is expected to further improve the accuracy of BC diagnosis.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Clinic Medicine, Chengdu Medical College, Sichuan, China.
- Department of Public Health, Chengdu Medical College, Sichuan, China.
- Art College, Southwest Minzu University, Sichuan, China.
- Department of Physiology, School of Basic Medicine, Chengdu Medical College, Sichuan, China.
Zitieren
APA
Zhang, H., Hu, J., Meng, R., Liu, F., Xu, F., & Huang, M. (2024). A systematic review and meta-analysis comparing the diagnostic capability of automated breast ultrasound and contrast-enhanced ultrasound in breast cancer. Frontiers in Oncology, 13. https://doi.org/10.3389/fonc.2023.1305545
Vancouver
Zhang H, Hu J, Meng R, Liu F, Xu F, Huang M. A systematic review and meta-analysis comparing the diagnostic capability of automated breast ultrasound and contrast-enhanced ultrasound in breast cancer. Frontiers in Oncology. 2024;13. doi:10.3389/fonc.2023.1305545
BibTeX
@article{Zhang2024,
author = {Zhang, Haoyu and Hu, Jingyi and Meng, Rong and Liu, Fangfang and Xu, Fan and Huang, Min},
title = {A systematic review and meta-analysis comparing the diagnostic capability of automated breast ultrasound and contrast-enhanced ultrasound in breast cancer},
journal = {Frontiers in Oncology},
year = {2024},
volume = {13},
doi = {10.3389/fonc.2023.1305545}
}