Automated Task-Transfer Function Measurement for CT Image Quality Assessment Based on AAPM TG 233
Journal of Imaging · 18.08.2025 · 11 (8) · 277
DOI: 10.3390/jimaging11080277 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Imaging, online erschienen am 18.08.2025. Verfasst von Choirul Anam und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Semarang 50275, Indonesia. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Diponegoro University.
Abstract (Originalsprache)
This study aims to develop and validate software for the automatic measurement of the task-transfer function (TTF) based on the American Association of Physicists in Medicine (AAPM) Task Group (TG) 233. The software consists of two main stages: automatic placement of the region of interest (ROI) within circular objects of the phantoms and calculating the TTF. The software was developed on four CT phantom types: computational phantom, ACR 464 CT phantom, AAPM CT phantom, and Catphan® 604 phantom. Each phantom was tested with varying parameters, including spatial resolution level, slice thickness, and image reconstruction technique. The results of TTF were compared with manual measurements performed using ImQuest version 7.3.01 and iQmetix-CT version v1.2. The software successfully located ROIs at all circular objects within each phantom and measured accurate TTF with various contrast-to-noise ratios (CNRs) of all phantoms. The TTF results were comparable to those obtained with ImQuest and iQmetrix-CT. It was found that the TTF curves produced by the software are smoother than those produced by ImQuest. An algorithm for the automated measurement of TTF was successfully developed and validated. TTF measurement with our software is highly user-friendly, requiring only a single click from the user.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Semarang 50275, Indonesia.
- Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok 16424, Indonesia.
- Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka 812-8582, Japan.
- Applied Physics and Medical Imaging, California State University Channel Islands, Camarillo, CA 93012, USA.
ORCID-Profile: Choirul Anam, Riska Amilia, Ariij Naufal, Heri Sutanto, Toshioh Fujibuchi, Geoff Dougherty
Förderung
- Diponegoro University
Zitieren
APA
Anam, C., Amilia, R., Naufal, A., Hidayanto, E., Sutanto, H., Lubis, L. E., Fujibuchi, T., & Dougherty, G. (2025). Automated Task-Transfer Function Measurement for CT Image Quality Assessment Based on AAPM TG 233. Journal of Imaging, 11(8), 277. https://doi.org/10.3390/jimaging11080277
Vancouver
Anam C, Amilia R, Naufal A, Hidayanto E, Sutanto H, Lubis LE, et al. Automated Task-Transfer Function Measurement for CT Image Quality Assessment Based on AAPM TG 233. Journal of Imaging. 2025;11(8):277. doi:10.3390/jimaging11080277
BibTeX
@article{Anam2025,
author = {Anam, Choirul and Amilia, Riska and Naufal, Ariij and Hidayanto, Eko and Sutanto, Heri and Lubis, Lukmanda E and Fujibuchi, Toshioh and Dougherty, Geoff},
title = {Automated Task-Transfer Function Measurement for CT Image Quality Assessment Based on AAPM TG 233},
journal = {Journal of Imaging},
year = {2025},
volume = {11},
number = {8},
pages = {277},
doi = {10.3390/jimaging11080277}
}
EUVIMED