Automated CO2 insufflation and image quality in CT colonography
Radiography · 2026-10 · 32 (7) · 103552
DOI: 10.1016/j.radi.2026.103552 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiography, 2026-10. Verfasst von J M Jensen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University Hospital of Southern Denmark, Vejle Hospital, Denmark; Department of Regional Health Research, University of Sout…. Hauptthemen laut MEDLINE: Colonography, Computed Tomographic, Carbon Dioxide, Insufflation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Southern Denmark.
Abstract (Originalsprache)
INTRODUCTION: CT colonography is an established technique for detecting polyps and colorectal cancer, particularly in patients unable to undergo conventional colonoscopy. The aim of this study was to evaluate the volume of automated CO2 insufflation, radiation dose, and diagnostic image quality in patients undergoing CT colonography. METHODS: This single-centre retrospective study included patients referred for CT colonography following incomplete or contraindicated colonoscopy. Examinations were performed in supine and prone positions. Radiation dose for each position was collected, including CT dose index volume (CTDI) and dose-length product (DLP). Colonic distention was graded from radiology reports by four radiologists using a five-point Likert scale (1 = poor, 5 = excellent); examinations were classified as diagnostic or non-diagnostic. Statistical analysis examined the association between CO2 insufflation volume and image quality. RESULTS: A total of 243 CT colonography examinations (188 women, 55 men; median age 71 years) were analysed. The median CO2 insufflation volume was 6 L (range 1.5-16 L). Median total DLP was 594 mGy cm (IQR 438.8-866.1). Overall, 222 examinations (91.4%) were considered diagnostic, while 21 (8.6%) were non-diagnostic. Colonic distention was rated as excellent in 131 cases (53.9%), good in 25 (10.3%), sufficient in 41 (16.9%), suboptimal in 35 (14.4%), and poor in 11 (4.5%). CONCLUSION: A median of 6 L of CO2 was used to achieve diagnostic colonic distention, with a median radiation dose of 594 mGy cm. Most examinations in the study achieved an image quality score of 4 or higher, sufficient for accurate interpretation. IMPLICATIONS FOR PRACTICE: Higher-than-expected CO2 volumes were observed, highlighting the importance of optimizing insufflation protocols to balance image quality, and standardization in clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, University Hospital of Southern Denmark, Vejle Hospital, Denmark; Department of Regional Health Research, University of Southern Denmark, Odense, Denmark. Electronic address: Josefine.magdalene.…
- Department of Radiology, University Hospital of Southern Denmark, Vejle Hospital, Denmark.
- Department of Radiology, University Hospital of Southern Denmark, Vejle Hospital, Denmark; Department of Regional Health Research, University of Southern Denmark, Odense, Denmark.
- Department of Radiology, University Hospital of Southern Denmark, Middelfart Hospital, Denmark.
- Department of Regional Health Research, University of Southern Denmark, Odense, Denmark; Department of Oncology, Vejle Hospital, University Hospital of Southern Denmark, Denmark.
- Department of Regional Health Research, University of Southern Denmark, Odense, Denmark; Department of Radiology, University Hospital of Southern Denmark, Kolding Hospital, Denmark.
Förderung
- University of Southern Denmark
Zitieren
APA
Jensen, J. M., Toft, D. M., Rafaelsen, S. R., Mørup, S. D., Hansen, T. F., Precht, H., & Pedersen, M. R. (2026). Automated CO2 insufflation and image quality in CT colonography. Radiography, 32(7), 103552. https://doi.org/10.1016/j.radi.2026.103552
Vancouver
Jensen JM, Toft DM, Rafaelsen SR, Mørup SD, Hansen TF, Precht H, et al. Automated CO2 insufflation and image quality in CT colonography. Radiography. 2026;32(7):103552. doi:10.1016/j.radi.2026.103552
BibTeX
@article{Jensen2026,
author = {Jensen, J M and Toft, D M and Rafaelsen, S R and Mørup, S D and Hansen, T F and Precht, H and Pedersen, M R},
title = {Automated CO2 insufflation and image quality in CT colonography},
journal = {Radiography},
year = {2026},
volume = {32},
number = {7},
pages = {103552},
doi = {10.1016/j.radi.2026.103552}
}