EUVIMEDSkopri EUVIMED
Open access · CC BY 4.0

Systematic Disagreement Between Skinfold-Derived and Dual-Energy X-Ray Absorptiometry (DXA) Body Fat Estimates in Elite Female Trail Runners

Nil Piñol-Granadino, Fabrizio Gravina-Cognetti, Marta Carrasco-Marginet, Joaquim Rosales, Sílvia Puigarnau, Neus Guinovart, Alfredo Irurtia

Journal of Functional Morphology and Kinesiology · 2026-11-17 · 11 (4) · 479

DOI: 10.3390/jfmk11040479 ↗

At a glance

Journal article in Journal of Functional Morphology and Kinesiology, published online on 2026-11-17. Written by Nil Piñol-Granadino and 6 co-authors. 57 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Institute of Physical Education of Catalonia (INEFC), Government of Catalonia.

AstrattDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background

Converting skinfold thicknesses into body fat percentage (%BF) assumes that subcutaneous adipose tissue (SAT) represents a fixed fraction of total fat, an assumption untested at extreme leanness. This study assessed whether skinfold–dual-energy X-ray absorptiometry (DXA) disagreement is random or structured by regional SAT.

Methods

Thirty-five elite (Tier 4) female trail runners underwent anthropometry (Withers equation) and DXA in one session. Agreement was evaluated via Bland–Altman analysis and Lin’s concordance correlation coefficient (CCC). The inter-method difference (%BF_GAP = %BF_WITHERS − %BF_DXA) was regressed on android SAT, adjusted for total adiposity, and benchmarked against DXA-derived negative controls.

Results

The methods correlated closely (r = 0.866) but showed poor concordance (CCC = 0.311). Skinfold estimates were systematically lower than DXA by 5.50 percentage points (pp; 95% limits of agreement −8.75 to −2.25 pp), with a proportional bias that widened with adiposity. Android SAT was associated with %BF_GAP (R2 = 0.489). Residualized on total fat mass, SAT retained an independent association (ΔR2 = 0.106), which no negative control showed. Propagated skinfold imprecision explained ~1.3% of the difference variance.

Conclusions

The methods were not interchangeable. Their disagreement was systematic and associated with android SAT, but the design cannot show which method is closer to true body fat. In comparable athletes, converted skinfold %BF should not be reported alone or compared against DXA reference data; raw skinfold sums are preferable, as a variable to be observed rather than a target to be reduced.

Funding

  • National Institute of Physical Education of Catalonia (INEFC), Government of Catalonia

Cite

APA

Piñol-Granadino, N., Gravina-Cognetti, F., Carrasco-Marginet, M., Rosales, J., Puigarnau, S., Guinovart, N., & Irurtia, A. (2026). Systematic Disagreement Between Skinfold-Derived and Dual-Energy X-Ray Absorptiometry (DXA) Body Fat Estimates in Elite Female Trail Runners. Journal of Functional Morphology and Kinesiology, 11(4), 479. https://doi.org/10.3390/jfmk11040479

Vancouver

Piñol-Granadino N, Gravina-Cognetti F, Carrasco-Marginet M, Rosales J, Puigarnau S, Guinovart N, et al. Systematic Disagreement Between Skinfold-Derived and Dual-Energy X-Ray Absorptiometry (DXA) Body Fat Estimates in Elite Female Trail Runners. Journal of Functional Morphology and Kinesiology. 2026;11(4):479. doi:10.3390/jfmk11040479

BibTeX
@article{PiolGranadino2026,
  author = {Piñol-Granadino, Nil and Gravina-Cognetti, Fabrizio and Carrasco-Marginet, Marta and Rosales, Joaquim and Puigarnau, Sílvia and Guinovart, Neus and Irurtia, Alfredo},
  title = {Systematic Disagreement Between Skinfold-Derived and Dual-Energy X-Ray Absorptiometry (DXA) Body Fat Estimates in Elite Female Trail Runners},
  journal = {Journal of Functional Morphology and Kinesiology},
  year = {2026},
  volume = {11},
  number = {4},
  pages = {479},
  doi = {10.3390/jfmk11040479}
}
Start for free →