Updated practice guideline for dual-energy X-ray absorptiometry (DXA)

Riemer H J A Slart, Marija Punda, Dalal S Ali, Alberto Bazzocchi, Oliver Bock, Pauline Camacho, John J Carey, Anita Colquhoun, Juliet Compston, Klaus Engelke, Paola A Erba, Nicholas C Harvey und 16 weitere

European Journal of Nuclear Medicine and Molecular Imaging · 2025-01 · 52 (2) · 539-563

DOI: 10.1007/s00259-024-06912-6 ↗

Kurz gefasst

Leitlinie in der Zeitschrift European Journal of Nuclear Medicine and Molecular Imaging, online erschienen am 24.09.2024. Verfasst von Riemer H J A Slart und 27 weiteren Autor:innen. Beteiligte Einrichtung: Medical Imaging Centre, Department of Nuclear Medicine & Molecular Imaging (EB50), University Medical Center Groningen, University of Groningen, Hanz…. Hauptthemen laut MEDLINE: Absorptiometry, Photon. Die Arbeit wurde bisher 159-mal zitiert (Crossref) und nennt 106 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The introduction of dual-energy X-ray absorptiometry (DXA) technology in the 1980s revolutionized the diagnosis, management and monitoring of osteoporosis, providing a clinical tool which is now available worldwide. However, DXA measurements are influenced by many technical factors, including the quality control procedures for the instrument, positioning of the patient, and approach to analysis. Reporting of DXA results may be confounded by factors such as selection of reference ranges for T-scores and Z-scores, as well as inadequate knowledge of current standards for interpretation. These points are addressed at length in many international guidelines but are not always easily assimilated by practising clinicians and technicians. Our aim in this report is to identify key elements pertaining to the use of DXA in clinical practice, considering both technical and clinical aspects. Here, we discuss technical aspects of DXA procedures, approaches to interpretation and integration into clinical practice, and the use of non-bone mineral density measurements, such as a vertebral fracture assessment, in clinical risk assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Absorptiometry, PhotonHumansOsteoporosisBone Density

Stichwörter der Autor:innen

Dual-energy X-ray absorptiometry (DXA)Practice guidelineProcedures

Autor:innen und Institutionen

  • Medical Imaging Centre, Department of Nuclear Medicine & Molecular Imaging (EB50), University Medical Center Groningen, University of Groningen, Hanzeplein 1, PO 9700 RB, Groningen, The Netherlands. r.h.j.a.slart@umcg.n…
  • Department of Oncology and Nuclear Medicine, University Hospital Centre Sestre Milosrdnice, Vinogradska 29, Zagreb, Croatia.
  • Department of Endocrinology, McMaster University, Hamilton, L8S 4L8, Canada.
  • Diagnostic and Interventional Radiology, IRCCS Istituto Ortopedico Rizzoli, Via G. C. Pupilli 1, Bologna, 40136, Italy.
  • Department of Osteoporosis, Inselspital, Bern University Hospital, Switzerland, IG Osteoporose, Bern, Switzerland.
  • Loyola University Medical Center (LUMC), 2160 S 1st Ave, Maywood, IL, 60153, USA.

Förderung

  • Medical Research Council

Zitieren

APA

Slart, R. H. J. A., Punda, M., Ali, D. S., Bazzocchi, A., Bock, O., Camacho, P., Carey, J. J., Colquhoun, A., Compston, J., Engelke, K., Erba, P. A., Harvey, N. C., Krueger, D., Lems, W. F., Lewiecki, E. M., Morgan, S., Moseley, K. F., O'Brien, C., Probyn, L., …, & International Working Group on DXA Best Practices (2025). Updated practice guideline for dual-energy X-ray absorptiometry (DXA). European Journal of Nuclear Medicine and Molecular Imaging, 52(2), 539-563. https://doi.org/10.1007/s00259-024-06912-6

Vancouver

Slart RHJA, Punda M, Ali DS, Bazzocchi A, Bock O, Camacho P, et al. Updated practice guideline for dual-energy X-ray absorptiometry (DXA). European Journal of Nuclear Medicine and Molecular Imaging. 2025;52(2):539-563. doi:10.1007/s00259-024-06912-6

BibTeX
@article{Slart2025,
  author = {Slart, Riemer H J A and Punda, Marija and Ali, Dalal S and Bazzocchi, Alberto and Bock, Oliver and Camacho, Pauline and Carey, John J and Colquhoun, Anita and Compston, Juliet and Engelke, Klaus and Erba, Paola A and Harvey, Nicholas C and Krueger, Diane and Lems, Willem F and Lewiecki, E Michael and Morgan, Sarah and Moseley, Kendall F and O'Brien, Christopher and Probyn, Linda and Rhee, Yumie and Richmond, Bradford and Schousboe, John T and Shuhart, Christopher and Ward, Kate A and Van den Wyngaert, Tim and Zhang-Yin, Jules and Khan, Aliya A and International Working Group on DXA Best Practices, International Working Group on DXA Best Practices},
  title = {Updated practice guideline for dual-energy X-ray absorptiometry (DXA)},
  journal = {European Journal of Nuclear Medicine and Molecular Imaging},
  year = {2025},
  volume = {52},
  number = {2},
  pages = {539--563},
  doi = {10.1007/s00259-024-06912-6}
}
Kostenlos starten →