EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fracture Resistance of 3D-Printed Partial and Conventional Veneers

Abdulrahman Alshabib iD, Silvia Rojas-Rueda iD, Saad Alotaibi iD, Carlos A Jurado, Mark A Antal iD, Brian R Morrow, Franklin Garcia-Godoy iD

Journal of Functional Biomaterials · 15.06.2026 · 17 (6) · 298

DOI: 10.3390/jfb17060298 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Functional Biomaterials, online erschienen am 15.06.2026. Verfasst von Abdulrahman Alshabib und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ongoing Research Funding program, King Saud University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The purpose of this in vitro study was to evaluate and compare the fracture resistance of 3D-printed partial veneers with finish lines at three different locations and conventional full veneers with finish lines at the gingival level. All restorations were digitally designed and 3D printed using a nanoceramic filled resin specifically developed for veneer restorations.

Methods

Four maxillary right central incisor typodont teeth were prepared for labial veneers with finish lines at different locations: incisal third (InT), middle portion of the middle third (MmT), lower portion of the middle third (LmT), and conventional veneer with the finish line at the gingival level (CoV). Each preparation was scanned, and 15 casts were 3D printed from each scan. A total of 60 3D-printed veneers were fabricated (n = 15 per group) using a nanoceramic-filled resin designed for veneer restorations. The restorations were cemented to the 3D-printed dies using the manufacturer’s adhesive and resin cement. The specimens were artificially aged with 10,000 thermal cycles between 5 °C and 55 °C, with a dwell time of 30 s, and then loaded to failure using a universal testing machine. Fracture load values were analyzed using one-way ANOVA and the Tukey honestly significant difference post hoc test (α = 0.05). In addition, fracture patterns were evaluated using scanning electron microscopy images for descriptive purposes.

Results

The mean fracture resistance of the 3D-printed partial and conventional labial veneers differed significantly depending on restoration design (p < 0.05). Among the partial veneers, the LmT group showed the highest fracture resistance (279.86 N), followed by the MmT group (266.92 N), while the InT group showed the lowest value (179.22 N). The conventional veneer group (CoV) demonstrated higher fracture resistance (404.07 N) than all partial veneer groups.

Conclusions

The fracture resistance of 3D-printed partial and conventional labial veneers fabricated with nanoceramic-filled resins differed according to finish line location. Conventional veneers demonstrated higher fracture resistance than all partial veneer designs. The smallest partial veneer, with the margin located in the incisal third, showed lower fracture resistance than the partial veneer designs with finish lines in the middle third.

Schlagwörter

Stichwörter der Autor:innen

3D-printeddentistrypartial veneersveneers

Autor:innen und Institutionen

  • Department of Restorative Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.
  • School of Dental Medicine, Ponce Health Sciences University, Ponce 00732, Puerto Rico.
  • Department of Operative and Esthetic Dentistry, Faculty of Dentistry, University of Szeged, 6720 Szeged, Hungary.
  • Department of Bioscience Research, College of Dentistry, The University of Tennessee Health Science Center, Memphis, TN 382014, USA.

ORCID-Profile: Abdulrahman Alshabib, Silvia Rojas-Rueda, Saad Alotaibi, Mark A Antal, Franklin Garcia-Godoy

Förderung

  • Ongoing Research Funding program
  • King Saud University

Zitieren

APA

Alshabib, A., Rojas-Rueda, S., Alotaibi, S., Jurado, C. A., Antal, M. A., Morrow, B. R., & Garcia-Godoy, F. (2026). Fracture Resistance of 3D-Printed Partial and Conventional Veneers. Journal of Functional Biomaterials, 17(6), 298. https://doi.org/10.3390/jfb17060298

Vancouver

Alshabib A, Rojas-Rueda S, Alotaibi S, Jurado CA, Antal MA, Morrow BR, et al. Fracture Resistance of 3D-Printed Partial and Conventional Veneers. Journal of Functional Biomaterials. 2026;17(6):298. doi:10.3390/jfb17060298

BibTeX
@article{Alshabib2026,
  author = {Alshabib, Abdulrahman and Rojas-Rueda, Silvia and Alotaibi, Saad and Jurado, Carlos A and Antal, Mark A and Morrow, Brian R and Garcia-Godoy, Franklin},
  title = {Fracture Resistance of 3D-Printed Partial and Conventional Veneers},
  journal = {Journal of Functional Biomaterials},
  year = {2026},
  volume = {17},
  number = {6},
  pages = {298},
  doi = {10.3390/jfb17060298}
}
Kostenlos starten →