Limited Accuracy of Tibial Stylus Measurements in Conventional Total Knee Arthroplasty
Journal of Clinical Medicine · 20.05.2026 · 15 (10) · 3935
DOI: 10.3390/jcm15103935 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 20.05.2026. Verfasst von Oliver Haider und 8 weiteren Autor:innen. Beteiligte Einrichtung: Vienna General Hospital, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Accurate tibial resection is important for component alignment and implant longevity in total knee arthroplasty (TKA). Despite the utilization of standardized instrumentation, discrepancies between predicted and actual resection depth persist. In the current study, the correlation between stylus-derived measurements and actual tibial resection thickness is analyzed.
Methods
A total of 109 patients undergoing primary TKA using the Legion system (Smith & Nephew, Memphis, TN, USA) were included. The intraoperative resection depth was measured with a stylus at the selected tibial reference point and compared with the caliper-measured osteochondral thickness of the resected tibial fragment at the same location. Correlations were assessed using Spearman’s rank correlation, while agreement was evaluated using Bland–Altman analysis.
Results
The mean stylus-indicated resection depth was 4.24 ± 2.15 mm, whereas the mean caliper-measured osteochondral thickness at the same marked reference point was 5.75 ± 2.30 mm. After adjustment for the 1.37 mm saw blade kerf, the mean osteochondral resection thickness was 7.12 ± 2.30 mm. The mean discrepancy between planned and kerf-adjusted osteochondral resection was −2.85 (SD = 1.99 mm; 95% CI: −3.22 to −2.47 mm) indicating a tendency toward over-resection. The correlation between stylus-indicated depth and actual osteochondral resection thickness was moderate (ρ = 0.540, p < 0.001). Bland–Altman analysis showed wide 95% limits of agreement from −6.75 to 1.05 mm.
Conclusions
Stylus-based predictions of tibial resection depth show limited accuracy. Stylus-based measurements should be interpreted with caution and complemented by intraoperative verification.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Vienna General Hospital, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria.
- Department of Orthopedic Surgery and Traumatology, Evangelisches Krankenhaus Wien, Hans-Sachs-Gasse 10-12, 1180 Vienna, Austria.
- Department of Orthopaedics, Wockhardt Hospital, Mira Road, Mumbai 400011, India.
- Department of Orthopaedic Surgery and Traumatology, Moventris Health Sciences, C103 Renaissance Exotica, Bengaluru 560001, India.
- Department of Orthopedic Surgery and Traumatology, Klinik Donaustadt, Langobardenstraße 122, 1220 Vienna, Austria.
ORCID-Profile: Oliver Haider, Tobias Scheidl, Anna Jungwirth-Weinberger, Darshan S Angadi, Maximilian F Kasparek, Thomas Muellner
Zitieren
APA
Haider, O., Scheidl, T., Jungwirth-Weinberger, A., Raje, A. D., Angadi, D. S., Buday, Z., Muellner, K., Kasparek, M. F., & Muellner, T. (2026). Limited Accuracy of Tibial Stylus Measurements in Conventional Total Knee Arthroplasty. Journal of Clinical Medicine, 15(10), 3935. https://doi.org/10.3390/jcm15103935
Vancouver
Haider O, Scheidl T, Jungwirth-Weinberger A, Raje AD, Angadi DS, Buday Z, et al. Limited Accuracy of Tibial Stylus Measurements in Conventional Total Knee Arthroplasty. Journal of Clinical Medicine. 2026;15(10):3935. doi:10.3390/jcm15103935
BibTeX
@article{Haider2026,
author = {Haider, Oliver and Scheidl, Tobias and Jungwirth-Weinberger, Anna and Raje, Amrut Diwakar and Angadi, Darshan S and Buday, Zoltan and Muellner, Katharina and Kasparek, Maximilian F and Muellner, Thomas},
title = {Limited Accuracy of Tibial Stylus Measurements in Conventional Total Knee Arthroplasty},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {10},
pages = {3935},
doi = {10.3390/jcm15103935}
}