EUVIMEDEUVIMED entdecken
Open Access

Accuracy of matching tibial slope in manual kinematically aligned total knee arthroplasty

Whisper Grayson, Ethan Teich, Nicholas M Brown

Journal of Orthopaedics · 2025-04 · 62 · 152-155

DOI: 10.1016/j.jor.2025.03.033 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedics, 2025-04. Verfasst von Whisper Grayson und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery & Rehabilitation, Loyola University Health System, Maywood, IL, USA. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Reproduction of the posterior tibial slope (PTS) during total knee arthroplasty (TKA) improves patient outcomes and minimizes complications including subsidence, polyethylene wear, and instability. The use of imaging has been previously studied as a way of measuring PTS angle and its association with surgical outcomes. There is a lack of literature on the accuracy of matching PTS during manual kinematically aligned (KA) TKA.

Methods

This is a retrospective study including 299 primary manual KA TKAs between October 2021 and August 2024 by a single surgeon. The primary outcome was comparison of pre-operative and post-operative PTS angles. Measurements were performed on lateral radiographs as the angle between the tangent line of the tibial plateau and a line perpendicular to the tibial shaft axis.

Results

The average pre-operative tibial slope was 10.3° (std dev, 4.8) compared to an average post-operative measurement of 5.3° (std dev, 3.2) (p < 0.00001). Range of motion improved post-operatively, with average extension increasing from 4.4° to 0.9° and flexion maintained from 118.5° to 117.2°. Complications were infrequent, with one superficial infection, two prosthetic joint infections requiring revision, two additional reoperations for polyethylene exchanges, and five manipulations under anesthesia with subsequent improvement in range of motion.

Conclusion

In this study, we found a significant difference in pre-operative and post-operative tibial slope angle on radiographic measurements following manual KA TKA.

Schlagwörter

Stichwörter der Autor:innen

Kinematic alignmentRange of motionTibial slopeTotal knee arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery & Rehabilitation, Loyola University Health System, Maywood, IL, USA.
  • Loyola University Stritch School of Medicine, Maywood, IL, USA.

Zitieren

APA

Grayson, W., Teich, E., & Brown, N. M. (2025). Accuracy of matching tibial slope in manual kinematically aligned total knee arthroplasty. Journal of Orthopaedics, 62, 152-155. https://doi.org/10.1016/j.jor.2025.03.033

Vancouver

Grayson W, Teich E, Brown NM. Accuracy of matching tibial slope in manual kinematically aligned total knee arthroplasty. Journal of Orthopaedics. 2025;62:152-155. doi:10.1016/j.jor.2025.03.033

BibTeX
@article{Grayson2025,
  author = {Grayson, Whisper and Teich, Ethan and Brown, Nicholas M},
  title = {Accuracy of matching tibial slope in manual kinematically aligned total knee arthroplasty},
  journal = {Journal of Orthopaedics},
  year = {2025},
  volume = {62},
  pages = {152--155},
  doi = {10.1016/j.jor.2025.03.033}
}
Kostenlos starten →