Accuracy of Intraocular Lens Power Calculation in Cataract Surgery Combined with Trabeculectomy in Open Angle Glaucoma
Journal of Clinical Medicine · 18.05.2026 · 15 (10) · 3883
DOI: 10.3390/jcm15103883 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 18.05.2026. Verfasst von Giulia Coco und 6 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmology Unit, Department of Clinical Sciences and Translational Medicine, University of Rome Tor Vergata, 00133 Rome, Italy. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: To assess the accuracy of several intraocular lens power calculation formulas in phacotrabeculectomy for open angle glaucoma.
Methods
Patients who underwent phacotrabeculectomy for open angle glaucoma were included. Refraction and biometry measurements were repeated at 3, 6 and ≥12 months. Prediction error (PE) and absolute error (AE) were calculated using the SRK/T, Holladay 1, Hoffer Q, Haigis, Kane, Emmetropia Verifying Optical (EVO) and Barrett Universal II formulas at ≥12 months, and their accuracy was compared using linear mixed-effects models accounting for repeated measurements within the same eye and inter-eye correlation.
Results
Sixty eyes from 40 patients were included. The linear mixed-effects model showed a significant overall effect of formula on PE (χ2(6) = 119.14, p < 0.001). Most formulas showed a tendency toward a hyperopic refractive shift, whereas Haigis showed a negative PE. Based on estimated marginal mean AE, the formulas were ranked as follows: EVO (0.548 D), Barrett Universal II (0.551 D), Holladay and SRK/T (0.561 D), Haigis (0.572 D), Kane (0.577 D) and Hoffer Q (0.617 D). However, the AE did not significantly differ among the formulas (χ2(6) = 3.75, p = 0.711). The percentage of eyes within ± 1.00D of PE ranged from 81.7% to 90% across the formulas (p > 0.05). Significant axial length shortening, anterior chamber deepening and mean keratometry reduction were detected postoperatively at ≥12 months (p < 0.05).
Conclusions
Despite postoperative ocular anatomic changes, all formulas showed acceptable refractive accuracy after phacotrabeculectomy. Although no significant difference in the AE was detected among the formulas, the PE differed significantly, with most formulas showing a tendency toward a hyperopic shift and Haigis showing a myopic shift. This inter-formula difference should be considered when selecting the refractive target, particularly when using formulas that tend toward hyperopic PE.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ophthalmology Unit, Department of Clinical Sciences and Translational Medicine, University of Rome Tor Vergata, 00133 Rome, Italy.
- Department of Ophthalmology, Policlinico Casilino, 00169 Rome, Italy.
- Department of Sense organs, University of Rome La Sapienza, 00161 Rome, Italy.
- IRCCS-Fondazione Bietti, 00184 Rome, Italy.
- Ophthalmology Unit, Department of Experimental Medicine, University of Rome Tor Vergata, 00133 Rome, Italy.
ORCID-Profile: Giulia Coco, Danilo Iannetta, Gloria Roberti
Zitieren
APA
Coco, G., Piccotti, G., Genova, F., Leucci, L., Iannetta, D., Roberti, G., & Nucci, C. (2026). Accuracy of Intraocular Lens Power Calculation in Cataract Surgery Combined with Trabeculectomy in Open Angle Glaucoma. Journal of Clinical Medicine, 15(10), 3883. https://doi.org/10.3390/jcm15103883
Vancouver
Coco G, Piccotti G, Genova F, Leucci L, Iannetta D, Roberti G, et al. Accuracy of Intraocular Lens Power Calculation in Cataract Surgery Combined with Trabeculectomy in Open Angle Glaucoma. Journal of Clinical Medicine. 2026;15(10):3883. doi:10.3390/jcm15103883
BibTeX
@article{Coco2026,
author = {Coco, Giulia and Piccotti, Giulia and Genova, Federica and Leucci, Lucrezia and Iannetta, Danilo and Roberti, Gloria and Nucci, Carlo},
title = {Accuracy of Intraocular Lens Power Calculation in Cataract Surgery Combined with Trabeculectomy in Open Angle Glaucoma},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {10},
pages = {3883},
doi = {10.3390/jcm15103883}
}
EUVIMED