Non-Invasive Hemodynamic Monitoring in Transcatheter Aortic Valve Implantation
Journal of Clinical Medicine · 28.05.2025 · 14 (11) · 3794
DOI: 10.3390/jcm14113794 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 28.05.2025. Verfasst von Thorald Stolte und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology and Cardiovascular Research Institute Basel (CRIB), University Hospital Basel, University of Basel, 4031 Basel, Switzerland. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swiss National Science Foundation, Prof. Dr. Max Cloëtta Foundation, the Margarete und Walter Lichtenstein-Stiftung, University Hospital Basel.
Abstract (Originalsprache)
Background/Objectives: Aortic valve stenosis (AS) is a prevalent cardiovascular condition among elderly patients frequently treated with Transcatheter Aortic Valve Implantation (TAVI). Traditional hemodynamic monitoring during TAVI relies on invasive methods. The ClearSight® Finger Cuff system offers a non-invasive alternative for continuous hemodynamic monitoring. To compare the reliability and feasibility of non-invasive hemodynamic monitoring with traditional invasive hemodynamic monitoring during TAVI procedures.
Methods
In this prospective observational study, patients undergoing elective TAVI were recruited from two tertiary hospitals between March and August 2023. Invasive hemodynamic measurements were obtained using arterial and pigtail catheters, with a subset undergoing right heart catheterization. Non-invasive measurements were captured using the ClearSight® system. Data on baseline characteristics, procedural details, and 30-day follow-up outcomes were collected.
Results
The study cohort comprised 50 patients (median age 82 years (IQR 78.0, 85.8), 50% female). Non-invasive measurements of cardiac output (CO), cardiac index (CI), and stroke volume (SV) were consistently lower than invasive measurements (CO: 4.1 vs. 4.8 L/min, p = 0.03; CI: 2.2 vs. 2.7 L/min/m2, p = 0.01, SV: 66 vs. 77 mL, p = 0.25). Non-invasive blood pressure readings were lower than invasive radial and aortic measurements before and after TAVI. Correlation of non- and invasive measurements was low but similar before and after TAVI (Mean percentage error of 52%).
Conclusions
The ClearSight® system provided lower absolute values for all evaluated hemodynamic parameters as well as low correlation compared to traditional methods pre- as well as post-interventional.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology and Cardiovascular Research Institute Basel (CRIB), University Hospital Basel, University of Basel, 4031 Basel, Switzerland.
- Centre for Heart Valve Innovation, St. Paul's Hospital, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.
- Department of Cardiac Surgery, University Hospital Basel, University of Basel, 4031 Basel, Switzerland.
ORCID-Profile: Thorald Stolte, Max Wagener, Christoph Kaiser, Felix Mahfoud, Thomas Nestelberger
Förderung
- Swiss National Science Foundation
- Prof. Dr. Max Cloëtta Foundation, the Margarete und Walter Lichtenstein-Stiftung
- University Hospital Basel
- Edwards Lifesciences
- Siemens
- Beckman Coulter
- Ortho Clinical Diagnostics
- Orion Pharma
Zitieren
APA
Stolte, T., Sathananthan, J., Reichl, J. J., Boeddinghaus, J., Wagener, M., Schöpflin, C., Kaiser, C., Leibundgut, G., Mahfoud, F., Wood, D., Webb, J. G., & Nestelberger, T. (2025). Non-Invasive Hemodynamic Monitoring in Transcatheter Aortic Valve Implantation. Journal of Clinical Medicine, 14(11), 3794. https://doi.org/10.3390/jcm14113794
Vancouver
Stolte T, Sathananthan J, Reichl JJ, Boeddinghaus J, Wagener M, Schöpflin C, et al. Non-Invasive Hemodynamic Monitoring in Transcatheter Aortic Valve Implantation. Journal of Clinical Medicine. 2025;14(11):3794. doi:10.3390/jcm14113794
BibTeX
@article{Stolte2025,
author = {Stolte, Thorald and Sathananthan, Janarthanan and Reichl, Jakob Johannes and Boeddinghaus, Jasper and Wagener, Max and Schöpflin, Christian and Kaiser, Christoph and Leibundgut, Gregor and Mahfoud, Felix and Wood, David and Webb, John G and Nestelberger, Thomas},
title = {Non-Invasive Hemodynamic Monitoring in Transcatheter Aortic Valve Implantation},
journal = {Journal of Clinical Medicine},
year = {2025},
volume = {14},
number = {11},
pages = {3794},
doi = {10.3390/jcm14113794}
}
EUVIMED