EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY-NC 4.0

Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring

Mizuki Miura iD, Yusuke Watanabe iD, Jo Omiya, Ken Kozuma iD

Catheterization and Cardiovascular Interventions · 13.11.2026

DOI: 10.1002/ccd.71010 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 13.11.2026. Verfasst von Mizuki Miura und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Teikyo University School of Medicine, Tokyo, Japan. Die Arbeit nennt 3 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An 89‐year‐old man with structural deterioration of a surgical aortic bioprosthesis and renal dysfunction underwent zero‐contrast transcatheter aortic valve‐in‐surgical valve (TAV‐in‐SAV) implantation. A SavvyWire provided continuous left ventricular pressure monitoring and rapid pacing during the procedure. After implantation of a 23‐mm self‐expanding valve, a residual transvalvular gradient was detected, prompting balloon postdilatation under rapid pacing. Repeat invasive hemodynamic assessment showed improvement, and echocardiography demonstrated a mean gradient of 12 mmHg. At 12 months, the patient was in New York Heart Association class I, with preserved renal function and a mean gradient of 8 mmHg. Continuous pressure monitoring may support intraprocedural assessment and guide valve optimization when contrast exposure is being avoided in patients with renal dysfunction.

Schlagwörter

Stichwörter der Autor:innen

aortic stenosishemodynamicsrenal dysfunctiontranscatheter aortic valve replacementvalve‐in‐valvezero contrast

Autor:innen und Institutionen

  • Division of Cardiology, Teikyo University School of Medicine, Tokyo, Japan.

ORCID-Profile: Mizuki Miura, Yusuke Watanabe, Ken Kozuma

Zitieren

APA

Miura, M., Watanabe, Y., Omiya, J., & Kozuma, K. (2026). Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.71010

Vancouver

Miura M, Watanabe Y, Omiya J, Kozuma K. Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.71010

BibTeX
@article{Miura2026,
  author = {Miura, Mizuki and Watanabe, Yusuke and Omiya, Jo and Kozuma, Ken},
  title = {Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.71010}
}
Kostenlos starten →