Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring
Catheterization and Cardiovascular Interventions · 13.11.2026
DOI: 10.1002/ccd.71010 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 13.11.2026. Verfasst von Mizuki Miura und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Teikyo University School of Medicine, Tokyo, Japan. Die Arbeit nennt 3 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
An 89‐year‐old man with structural deterioration of a surgical aortic bioprosthesis and renal dysfunction underwent zero‐contrast transcatheter aortic valve‐in‐surgical valve (TAV‐in‐SAV) implantation. A SavvyWire provided continuous left ventricular pressure monitoring and rapid pacing during the procedure. After implantation of a 23‐mm self‐expanding valve, a residual transvalvular gradient was detected, prompting balloon postdilatation under rapid pacing. Repeat invasive hemodynamic assessment showed improvement, and echocardiography demonstrated a mean gradient of 12 mmHg. At 12 months, the patient was in New York Heart Association class I, with preserved renal function and a mean gradient of 8 mmHg. Continuous pressure monitoring may support intraprocedural assessment and guide valve optimization when contrast exposure is being avoided in patients with renal dysfunction.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology, Teikyo University School of Medicine, Tokyo, Japan.
ORCID-Profile: Mizuki Miura, Yusuke Watanabe, Ken Kozuma
Zitieren
APA
Miura, M., Watanabe, Y., Omiya, J., & Kozuma, K. (2026). Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.71010
Vancouver
Miura M, Watanabe Y, Omiya J, Kozuma K. Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.71010
BibTeX
@article{Miura2026,
author = {Miura, Mizuki and Watanabe, Yusuke and Omiya, Jo and Kozuma, Ken},
title = {Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
doi = {10.1002/ccd.71010}
}
EUVIMED