EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Initial Real-World Experiences of Pulmonary Vein Isolation and Ablation of Non-Pulmonary Vein Sites Using a Novel Circular Array Pulsed Field Ablation Catheter

Joerg Yogarajah iD, Julie Hutter, Patrick Kahle, Philipp Beaujean, Marko Tomic, Andreas Hain, Samuel Sossalla, Malte Kuniss, Thomas Neumann

Journal of Clinical Medicine · 19.11.2024 · 13 (22) · 6961

DOI: 10.3390/jcm13226961 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 19.11.2024. Verfasst von Joerg Yogarajah und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Kerckhoff Heart and Thorax Center, Campus Kerckhoff, Justus Liebig University Giessen, 61231 Bad Nauheim, Germany. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aims: Various pulsed field ablation (PFA) systems are currently being developed. Recently, a novel CE-approved circular array PFA catheter (PulseSelect™ PFA System, Medtronic, Minneapolis, MN, USA) was introduced. Data on this commercially available system are sparse. The aim was to elucidate real-world data assessing the feasibility, safety, and acute efficacy of pulmonary vein isolation (PVI) and ablation beyond PVI with this novel ablation system.

Methods

Consecutive patients with paroxysmal and persistent atrial fibrillation (AF) undergoing first-time ablation with the circular PFA catheter were enrolled in this study. In patients with persistent AF and left atrial (LA) enlargement (LA area > 20 cm2), additional left atrial roof ablation (LARA) was performed. Those with concomitant typical atrial flutter received adjunctive cavo-tricuspid isthmus (CTI) ablation.

Results

A total of 100 AF patients were included (29% female, 50% persistent AF). Of these, 33 patients (33%) underwent adjunctive LARA, 1 patient (1%) received posterior wall isolation, and 6 patients (6%) required additional CTI ablation. The skin-to-skin procedural time averaged 66.3 ± 13.8 min, while the fluoroscopy time and dose area product were 13.7 ± 4.7 min and 6.8 ± 4.9 Gycm2, respectively. Acute PVI was achieved in 100% of pulmonary veins. A bidirectional conduction block of the LARA and CTI lines was confirmed in all patients, and no major adverse events were reported.

Conclusions

These real-world data demonstrate the feasibility, safety, and acute efficacy of PVI and ablation beyond PVI using a novel circular array PFA catheter in patients with atrial fibrillation and flutter. The system can easily be integrated with standard PVI workflows. Further and larger studies are warranted to assess the clinical long-term effectiveness and safety of this PFA system.

Schlagwörter

Stichwörter der Autor:innen

atrial fibrillationcavo-tricuspid isthmus ablationleft atrial roof ablationpulmonary vein isolationpulsed field ablation

Autor:innen und Institutionen

  • Department of Cardiology, Kerckhoff Heart and Thorax Center, Campus Kerckhoff, Justus Liebig University Giessen, 61231 Bad Nauheim, Germany.
  • Department of Cardiology, Medical Clinic I, Justus Liebig University Giessen, 35392 Giessen, Germany.

ORCID-Profile: Joerg Yogarajah

Zitieren

APA

Yogarajah, J., Hutter, J., Kahle, P., Beaujean, P., Tomic, M., Hain, A., Sossalla, S., Kuniss, M., & Neumann, T. (2024). Initial Real-World Experiences of Pulmonary Vein Isolation and Ablation of Non-Pulmonary Vein Sites Using a Novel Circular Array Pulsed Field Ablation Catheter. Journal of Clinical Medicine, 13(22), 6961. https://doi.org/10.3390/jcm13226961

Vancouver

Yogarajah J, Hutter J, Kahle P, Beaujean P, Tomic M, Hain A, et al. Initial Real-World Experiences of Pulmonary Vein Isolation and Ablation of Non-Pulmonary Vein Sites Using a Novel Circular Array Pulsed Field Ablation Catheter. Journal of Clinical Medicine. 2024;13(22):6961. doi:10.3390/jcm13226961

BibTeX
@article{Yogarajah2024,
  author = {Yogarajah, Joerg and Hutter, Julie and Kahle, Patrick and Beaujean, Philipp and Tomic, Marko and Hain, Andreas and Sossalla, Samuel and Kuniss, Malte and Neumann, Thomas},
  title = {Initial Real-World Experiences of Pulmonary Vein Isolation and Ablation of Non-Pulmonary Vein Sites Using a Novel Circular Array Pulsed Field Ablation Catheter},
  journal = {Journal of Clinical Medicine},
  year = {2024},
  volume = {13},
  number = {22},
  pages = {6961},
  doi = {10.3390/jcm13226961}
}
Kostenlos starten →