Durability of Pulmonary Vein Isolation Using Pulsed-Field Ablation
JACC: Clinical Electrophysiology · 2024-04 · 10 (4) · 698-708
DOI: 10.1016/j.jacep.2023.11.026 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift JACC: Clinical Electrophysiology, 2024-04. Verfasst von Thomas Kueffer und 19 weiteren Autor:innen. Beteiligte Einrichtung: Inselspital-Bern University Hospital, University of Bern, Bern, Switzerland. Hauptthemen laut MEDLINE: Pulmonary Veins, Atrial Fibrillation, Registries, Catheter Ablation. Die Arbeit wurde bisher 88-mal zitiert (Crossref) und nennt 16 Literaturangaben. Gefördert von: Boston Scientific Corp.
Abstract (Originalsprache)
BACKGROUND: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology with high procedural safety and efficiency for pulmonary vein isolation (PVI). Premarket data showed high PVI durability during mandatory remapping studies. Data on lesion durability in real-world patients with clinically indicated redo procedures are scarce. OBJECTIVES: This study sought to report PVI durability rates in patients undergoing a clinically indicated redo procedure after an index PVI using PFA. METHODS: Patients from 7 European centers undergoing an index PVI using PFA were included the EU-PORIA (European Real-world Outcomes With Pulsed Field Ablation in Patients With Symptomatic Atrial Fibrillation) registry. In patients with subsequent left atrial redo procedures due to arrhythmia recurrence, 3-dimensional electroanatomical maps were acquired. PVI durability was assessed on a per-vein and per-patient level, and sites of reconnections and predictors of lesion durability were identified. RESULTS: Of 1,184 patients (62% paroxysmal atrial fibrillation) undergoing an index PVI using PFA, 272 (23%) had an arrhythmia recurrence. Of these, 144 (53%) underwent a left atrial redo procedure a median of 7 (Q1-Q3: 5-10) months after the first ablation. Three-dimensional electroanatomical maps identified 404 of 567 pulmonary veins (71%) with durable isolation. In 54 patients (38%), all pulmonary veins were durably isolated. Prior operator experience with cryoballoon ablation was associated with a higher PVI durability compared to operators with only point-by-point radiofrequency experience (76% vs 60%; P 5 years) nor the size of the PFA device used (31 mm vs 35 mm) had an impact on subsequent lesion durability (both P > 0.50). CONCLUSIONS: In 144 patients with arrhythmia recurrence after PFA PVI, durable isolation was observed in 71% of the pulmonary veins during the redo procedure, and 38% of all patients showed durable isolation of all veins.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Inselspital-Bern University Hospital, University of Bern, Bern, Switzerland.
- Cardioangiologisches Centrum Bethanien, Frankfurt, Germany.
- Department of Electrophysiology, Alfried Krupp Hospital, Essen, Germany; Department of Medicine, Witten/Herdecke University, Witten, Germany.
- Department of Cardiology, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
- Arrhythmia Unit, Department of Cardiology, Gentofte Hospital, Copenhagen, Denmark.
- Heart Rhythm Department, Clinique Pasteur, Toulouse, France.
Förderung
- Boston Scientific Corp
Zitieren
APA
Kueffer, T., Bordignon, S., Neven, K., Blaauw, Y., Hansen, J., Adelino, R., Ouss, A., Füting, A., Roten, L., Mulder, B. A., Ruwald, M. H., Mené, R., van der Voort, P., Reinsch, N., Boveda, S., Albrecht, E. M., Schneider, C. W., Chun, K. R. J., Schmidt, B., & Reichlin, T. (2024). Durability of Pulmonary Vein Isolation Using Pulsed-Field Ablation. JACC: Clinical Electrophysiology, 10(4), 698-708. https://doi.org/10.1016/j.jacep.2023.11.026
Vancouver
Kueffer T, Bordignon S, Neven K, Blaauw Y, Hansen J, Adelino R, et al. Durability of Pulmonary Vein Isolation Using Pulsed-Field Ablation. JACC: Clinical Electrophysiology. 2024;10(4):698-708. doi:10.1016/j.jacep.2023.11.026
BibTeX
@article{Kueffer2024,
author = {Kueffer, Thomas and Bordignon, Stefano and Neven, Kars and Blaauw, Yuri and Hansen, Jim and Adelino, Raquel and Ouss, Alexandre and Füting, Anna and Roten, Laurent and Mulder, Bart A and Ruwald, Martin H and Mené, Roberto and van der Voort, Pepijn and Reinsch, Nico and Boveda, Serge and Albrecht, Elizabeth M and Schneider, Christopher W and Chun, K R Julian and Schmidt, Boris and Reichlin, Tobias},
title = {Durability of Pulmonary Vein Isolation Using Pulsed-Field Ablation},
journal = {JACC: Clinical Electrophysiology},
year = {2024},
volume = {10},
number = {4},
pages = {698--708},
doi = {10.1016/j.jacep.2023.11.026}
}
EUVIMED