EUVIMEDEUVIMED entdecken
Crossref

Effects of Pulsed Field Ablation for Pulmonary Vein Isolation on Vein of Marshall Electrograms

Yosuke Nakatani, Shuntaro Tamura, Hiroshi Hasegawa, Ryutaro Iwai, Takashi Kobari, Tadashi Nakajima, Yoshiaki Kaneko, Hideki Ishii

JACC: Clinical Electrophysiology · 2026-07

DOI: 10.1016/j.jacep.2026.06.015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2026-07. Verfasst von Yosuke Nakatani und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Non-pharmacological Management of Cardiac Arrhythmias, Gunma University Graduate School of Medicine, Japan. Electronic address: yosuke.na…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Pulsed field ablation (PFA) creates lesions without direct tissue contact and may affect adjacent nontarget structures. Given the close anatomical relationship between the vein of Marshall (VoM) and the left pulmonary veins (PVs), PFA-based PV isolation may influence VoM electrograms. OBJECTIVES: This study aimed to characterize real-time changes in VoM electrograms during PFA-based PV isolation. METHODS: A total of 72 patients undergoing PFA-based PV isolation were studied (FARAPULSE, n = 28; VARIPULSE, n = 21; PulseSelect, n = 23). A 1.6-F electrode catheter was positioned within the VoM to continuously record electrograms during the procedure. RESULTS: VoM electrograms were eliminated in 16 patients (22%) and reduced in 16 patients (22%). The extent of VoM electrogram alteration differed among PFA systems and was greatest with FARAPULSE (P < 0.001). Electrogram effects were strongly associated with the PFA electrode-VoM distance (median [Q1-Q3]) (no effect, 5.7 millimeters [4.1-7.5 millimeters]; reduction, 3.0 millimeters [2.9-3.7 millimeters]; elimination, 1.8 millimeters [1.5-2.2 millimeters]; P < 0.001). Among patients with acute VoM electrogram elimination, persistent elimination was observed in 9 patients (56%), whereas partial recovery occurred in 1 patient (6%) and complete restoration occurred in 6 patients (38%) by the end of the procedure. All patients with acute VoM electrogram reduction showed complete recovery. Overall, persistent VoM electrogram modification was observed in 14% of patients undergoing PFA-based PV isolation. CONCLUSIONS: The impact of PFA on VoM electrograms varied among PFA systems and was largely determined by the PFA electrode-VoM distance. Notably, the majority of VoM electrogram alterations were transient.

Schlagwörter

Stichwörter der Autor:innen

atrial fibrillationelectrogramspulmonary vein isolationpulsed field ablationvein of Marshall

Autor:innen und Institutionen

  • Division of Non-pharmacological Management of Cardiac Arrhythmias, Gunma University Graduate School of Medicine, Japan. Electronic address: yosuke.nakatani@gunma-u.ac.jp.
  • Department of Cardiovascular Medicine, Gunma University Graduate School of Medicine, Japan.

Zitieren

APA

Nakatani, Y., Tamura, S., Hasegawa, H., Iwai, R., Kobari, T., Nakajima, T., Kaneko, Y., & Ishii, H. (2026). Effects of Pulsed Field Ablation for Pulmonary Vein Isolation on Vein of Marshall Electrograms. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2026.06.015

Vancouver

Nakatani Y, Tamura S, Hasegawa H, Iwai R, Kobari T, Nakajima T, et al. Effects of Pulsed Field Ablation for Pulmonary Vein Isolation on Vein of Marshall Electrograms. JACC: Clinical Electrophysiology. 2026. doi:10.1016/j.jacep.2026.06.015

BibTeX
@article{Nakatani2026,
  author = {Nakatani, Yosuke and Tamura, Shuntaro and Hasegawa, Hiroshi and Iwai, Ryutaro and Kobari, Takashi and Nakajima, Tadashi and Kaneko, Yoshiaki and Ishii, Hideki},
  title = {Effects of Pulsed Field Ablation for Pulmonary Vein Isolation on Vein of Marshall Electrograms},
  journal = {JACC: Clinical Electrophysiology},
  year = {2026},
  doi = {10.1016/j.jacep.2026.06.015}
}
Kostenlos starten →