Predictive Accuracy of Intraocular Lens Formulas Calculated by Biometers with Multiple Refractive Indices According to Axial Length
Journal of Clinical Medicine · 13.11.2024 · 13 (22) · 6815
DOI: 10.3390/jcm13226815 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 13.11.2024. Verfasst von Yeo Kyoung Won und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
Background/Objectives: This study aimed to analyze the accuracy of the SRK/T, Haigis, Barrett Universal II (BUII), Kane, and EVO intraocular lens (IOL) formulas for normal and long axial length (AL) groups using an ARGOS (Alcon, Fort Worth, TX, USA), which uses the specific refractive indices.
Methods
We performed a review of patients who underwent uneventful cataract surgery with the implantation of an Acrysof IQ SN60WF IOL (Alcon, Inc.) between January 2020 and December 2021. Biometry was obtained with the ARGOS; patients were separated into subgroups based on AL as follows: normal (22.0 ≤ AL < 26.0 mm) and long (AL ≥ 26.0 mm). Outcomes included the mean error (ME), the mean absolute error (MAE), the median absolute error (MedAE), and the proportion of eyes within ±0.25, ±0.50, ±0.75, and ±1.00 diopters (D) of the prediction error.
Results
A total of 191 eyes of 191 patients were included: 162 eyes of 162 patients in the normal AL group and 29 eyes of 29 patients in the long AL group. The EVO formula was the most accurate for the normal AL group, which had the lowest MAE and MedAE. The MAE and MedAE of EVO were the lowest in the long AL group; EVO showed the highest percentage of eyes within ±0.25, ±0.75, and 1.00 D compared with other formulas.
Conclusions
When using an ARGOS, the EVO formula had the lowest MAE and the highest proportion of eyes within ±1.00 D of the predicted target in both the normal and high myopia groups.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea.
- IU Eye Clinic, Seoul 05606, Republic of Korea.
- Renew Seoul Eye Center, Seoul 06181, Republic of Korea.
- Department of Medical Device Management and Research, Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University, Seoul 06351, Republic of Korea.
ORCID-Profile: Yeo Kyoung Won, Dong Hui Lim
Förderung
- National Research Foundation of Korea
Zitieren
APA
Won, Y. K., Yoo, Y. S., Yun, H. J., Chung, T. Y., & Lim, D. H. (2024). Predictive Accuracy of Intraocular Lens Formulas Calculated by Biometers with Multiple Refractive Indices According to Axial Length. Journal of Clinical Medicine, 13(22), 6815. https://doi.org/10.3390/jcm13226815
Vancouver
Won YK, Yoo YS, Yun HJ, Chung TY, Lim DH. Predictive Accuracy of Intraocular Lens Formulas Calculated by Biometers with Multiple Refractive Indices According to Axial Length. Journal of Clinical Medicine. 2024;13(22):6815. doi:10.3390/jcm13226815
BibTeX
@article{Won2024,
author = {Won, Yeo Kyoung and Yoo, Young-Sik and Yun, Hee-Jee and Chung, Tae-Young and Lim, Dong Hui},
title = {Predictive Accuracy of Intraocular Lens Formulas Calculated by Biometers with Multiple Refractive Indices According to Axial Length},
journal = {Journal of Clinical Medicine},
year = {2024},
volume = {13},
number = {22},
pages = {6815},
doi = {10.3390/jcm13226815}
}
EUVIMED