EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Evaluating predictive accuracy of intraocular lens power calculation formulas in high axial myopia: A comparative analysis

Teck Chee Cheng, Thayaletchumy Gopala Krishnan, Jemaima Che Hamzah

Indian Journal of Ophthalmology · 2026-05 · 74 (Suppl 1) · S66-S73

DOI: 10.4103/ijo.ijo_2193_25 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Indian Journal of Ophthalmology, online erschienen am 30.04.2026. Verfasst von Teck Chee Cheng und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Yaakob Latiff, Bandar Tun Razak, Cheras, Kuala Lumpur, Malays…. Hauptthemen laut MEDLINE: Lenses, Intraocular, Refraction, Ocular, Biometry, Optics and Photonics. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the precision of six intraocular lens (IOL) power calculation formulas—Barrett Universal II, SRK/T, Haigis, Holladay I, Holladay II, and Hoffer Q—among myopic patients undergoing cataract surgery.

Methods

This retrospective study included 164 eyes from 131 patients with an axial length (AL) greater than 26.0 mm who underwent uncomplicated cataract surgery with monofocal IOL implantation at a tertiary referral center between 2018 and 2021 Several biometric data points were recorded using the IOLMaster 700. Additionally, refractive prediction error was observed and defined as the difference between predicted and postoperative spherical equivalents. Formula performance was assessed using mean absolute error (MAE), mean numerical error, median absolute error, and proportion of eyes achieving predefined refractive accuracy (±0.25 D, ±0.50 D, ±1.00 D, and ± 2.00 D).

Results

Barrett Universal II showed the lowest calculation of MAE (0.54 ± 0.71 D), followed by SRK/T (0.57 ± 0.75 D) and Haigis (0.61 ± 0.69 D). Barrett Universal II demonstrated significant predictive accuracy compared with Holladay I, Holladay II, and Hoffer Q ( P < 0.05), while no statistically significant differences were observed when compared to SRK/T and Haigis. Besides, it resulted in the highest proportions of eyes within ± 0.25 D (36.6%), ±0.50 D (59.1%), ±1.00 D (88.4%), and ± 2.00 D (98.8%). The absolute prediction error increased with AL ( P < 0.05), whereas there was no significant correlation with keratometry.

Conclusion

In highly myopic eyes, Barrett Universal II showed numerically lower refractive prediction errors, with overall accuracy comparable to SRK/T and Haigis. No formula demonstrated consistent statistical superiority, indicating broadly equivalent performance among the leading formulas in this population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularRefraction, OcularBiometryOptics and PhotonicsVisual AcuityLens Implantation, IntraocularMyopiaMyopia, DegenerativeHumansRetrospective StudiesFemaleMaleAxial Length, EyeMiddle AgedAgedReproducibility of Results

Stichwörter der Autor:innen

Axial lengthBarrett Universal IIhigh axial myopiaintraocular lens power calculation formularefractive prediction error

Autor:innen und Institutionen

  • Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Yaakob Latiff, Bandar Tun Razak, Cheras, Kuala Lumpur, Malaysia.
  • Department of Ophthalmology, Hospital Canselor Tuanku Muhriz, Jalan Yaakob Latiff, Bandar Tun Razak, Cheras, Kuala Lumpur, Malaysia.

Zitieren

APA

Cheng, T. C., Gopala Krishnan, T., & Che Hamzah, J. (2026). Evaluating predictive accuracy of intraocular lens power calculation formulas in high axial myopia: A comparative analysis. Indian Journal of Ophthalmology, 74(Suppl 1), S66-S73. https://doi.org/10.4103/ijo.ijo_2193_25

Vancouver

Cheng TC, Gopala Krishnan T, Che Hamzah J. Evaluating predictive accuracy of intraocular lens power calculation formulas in high axial myopia: A comparative analysis. Indian Journal of Ophthalmology. 2026;74(Suppl 1):S66-S73. doi:10.4103/ijo.ijo_2193_25

BibTeX
@article{Cheng2026,
  author = {Cheng, Teck Chee and Gopala Krishnan, Thayaletchumy and Che Hamzah, Jemaima},
  title = {Evaluating predictive accuracy of intraocular lens power calculation formulas in high axial myopia: A comparative analysis},
  journal = {Indian Journal of Ophthalmology},
  year = {2026},
  volume = {74},
  number = {Suppl 1},
  pages = {S66--S73},
  doi = {10.4103/ijo.ijo_2193_25}
}
Kostenlos starten →