Totally Endoscopic Replacement of the Ascending Aorta and the Aortic Root including the Aortic Valve via Right Mini-Thoracotomy: A Multicenter Study
Journal of Clinical Medicine · 30.04.2024 · 13 (9) · 2648
DOI: 10.3390/jcm13092648 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 30.04.2024. Verfasst von Marwan Hamiko und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, University Hospital Bonn, Venusberg Campus 1, 53127 Bonn, Germany. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Recently, minimally invasive access via right anterolateral mini-thoracotomy (RAMT) has been gaining popularity in cardiac surgery. This approach is also an option for surgeons performing aortic surgery. The aim of this study is to present our surgical method, highlighting the total endoscopic minimally invasive approach via RAMT for replacement of the ascending aorta (AAR) with or without involvement of the aortic root and the aortic valve.
Methods
Clinical data of 44 patients from three participating institutions with AAR with or without involvement of the aortic valve or aortic root via RAMT between April 2017 and February 2024 were retrospectively analyzed. According to surgical procedure, patients were divided into two groups, in the AAR and in the Wheat/Bentall group with concomitant valve or root replacement. Operative time, length of ventilation, perioperative outcome, length of intensive care unit (ICU) as well as postoperative hospital stay, and mid- and long-term results were retrospectively analyzed.
Results
Mean age was 61.4 ± 10.7 years old with a frequency of male gender of 63.6%. Mean cardiopulmonary bypass (CBP) time and aortic cross-clamping time was 94.9 ± 32.5 min and 63.8 ± 25.9 min, respectively. CPB and aortic clamp time were significantly lower in AAR group. In the first 24 h, the mean drainage volume was 790.3 ± 423.6 mL. Re-thoracotomy due to bleeding was zero. Sternotomy was able to be avoided in all patients. Patients stayed 35.9 ± 23.5 h at ICU and were discharged 7.8 ± 3.0 days following surgery from hospital. Mean ventilation time was 5.8 ± 7.6 h. All patients survived and 30-day mortality was 0.0%. At a median follow-up time of 18.2 months, all patients were alive. The results were similar in both groups.
Conclusions
The full endoscopic RAMT approach with 3D visualization is a safe, feasible and promising technique that can be transferred in the field of aortic surgery without compromising surgical quality, postoperative outcomes, or patient safety when performed by an experienced team in a high-volume center.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac Surgery, University Hospital Bonn, Venusberg Campus 1, 53127 Bonn, Germany.
- Department of Cardiac Surgery, Helios Hospital Siegburg, 53721 Siegburg, Germany.
- Department of Cardiac Surgery, Helios Hospital Wuppertal, 42283 Wuppertal, Germany.
ORCID-Profile: Marwan Hamiko, Saad Salamate
Zitieren
APA
Hamiko, M., Salamate, S., Nassari, M. A., Spaeth, A., Sirat, S., Doss, M., Amer, M., Silaschi, M., Ahmad, A. E., & Bakhtiary, F. (2024). Totally Endoscopic Replacement of the Ascending Aorta and the Aortic Root including the Aortic Valve via Right Mini-Thoracotomy: A Multicenter Study. Journal of Clinical Medicine, 13(9), 2648. https://doi.org/10.3390/jcm13092648
Vancouver
Hamiko M, Salamate S, Nassari MA, Spaeth A, Sirat S, Doss M, et al. Totally Endoscopic Replacement of the Ascending Aorta and the Aortic Root including the Aortic Valve via Right Mini-Thoracotomy: A Multicenter Study. Journal of Clinical Medicine. 2024;13(9):2648. doi:10.3390/jcm13092648
BibTeX
@article{Hamiko2024,
author = {Hamiko, Marwan and Salamate, Saad and Nassari, Maedeh Ayay and Spaeth, Andre and Sirat, Sami and Doss, Mirko and Amer, Mohamed and Silaschi, Miriam and Ahmad, Ali El-Sayed and Bakhtiary, Farhad},
title = {Totally Endoscopic Replacement of the Ascending Aorta and the Aortic Root including the Aortic Valve via Right Mini-Thoracotomy: A Multicenter Study},
journal = {Journal of Clinical Medicine},
year = {2024},
volume = {13},
number = {9},
pages = {2648},
doi = {10.3390/jcm13092648}
}