Totally endoscopic aortic valve replacement: Techniques and early results
Frontiers in Cardiovascular Medicine · 09.01.2023 · 9
DOI: 10.3389/fcvm.2022.1106845 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 09.01.2023. Verfasst von Wenda Gu und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Gua…. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Science and Technology Foundation of Guangdong Province, Basic and Applied Basic Research Foundation of Guangdong Province.
Abstract (Originalsprache)
Objective
To demonstrate the technical details of total endoscopic aortic valve replacement using a standard prosthesis, compare the clinical effect and safety of endoscopic aortic valve replacement and traditional aortic valve replacement.
Methods
From 2020 to 2021, 60 consecutive patients underwent elective isolated aortic valve replacement (AVR). They were divided into two groups: the total endoscopic AVR group (TE-AVR group, 29 patients, nine women, aged 51.65 ± 11.79 years), and the traditional full-sternotomy group (AVR group, 31 patients, 13 women, aged 54.23 ± 12.06 years). Three working ports were adopted in the TE-AVR procedure.
Results
No patient died in either group. The cardiopulmonary bypass (CPB) time and aortic cross-clamp (ACC) time in the TE-AVR group were longer than those in the AVR group (CPB time: 177.6 ± 43.2 vs. 112.1 ± 18.1 min, p < 0.001; ACC time: 118.3 ± 29.7 vs. 67.0 ± 13.2 min, p < 0.001). However, the mechanical ventilation duration (14.2 ± 9.3 vs. 24.0 ± 18.9 h, p = 0.015) and postoperative hospital stay (6.0 ± 1.7 vs. 8.0 ± 4.5 days, p = 0.025) were shorter in patients of TE-AVR group than those of AVR group. Although the ICU stay (55.1 ± 26.9 vs. 61.5 ± 44.8 h, p = 0.509) and post-operative chest drainage of the first 24 h (229.8 ± 125.0 vs. 273.2 ± 103.2 ml, p = 0.146) revealed no statistical difference, there was a decreasing trend in the TE-AVR group. Among the patients of the TE-AVR group, two patients were converted to thoracotomy because of mild to moderate paravalvular leakage identified by intraoperative transesophageal echocardiography.
Conclusion
Total endoscopic aortic valve replacement is safe and feasible, with less trauma and quicker recovery.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
- The Second School of Clinical Medicine, Southern Medical University, Guangzhou, China.
Förderung
- Medical Science and Technology Foundation of Guangdong Province
- Basic and Applied Basic Research Foundation of Guangdong Province
Zitieren
APA
Gu, W., Zhou, K., Wang, Z., Zang, X., Guo, H., Gao, Q., Teng, Y., Liu, J., He, B., Guo, H., & Huang, H. (2023). Totally endoscopic aortic valve replacement: Techniques and early results. Frontiers in Cardiovascular Medicine, 9. https://doi.org/10.3389/fcvm.2022.1106845
Vancouver
Gu W, Zhou K, Wang Z, Zang X, Guo H, Gao Q, et al. Totally endoscopic aortic valve replacement: Techniques and early results. Frontiers in Cardiovascular Medicine. 2023;9. doi:10.3389/fcvm.2022.1106845
BibTeX
@article{Gu2023,
author = {Gu, Wenda and Zhou, Kan and Wang, Zhenzhong and Zang, Xin and Guo, Haijiang and Gao, Qiang and Teng, Yun and Liu, Jian and He, Biaochuan and Guo, Huiming and Huang, Huanlei},
title = {Totally endoscopic aortic valve replacement: Techniques and early results},
journal = {Frontiers in Cardiovascular Medicine},
year = {2023},
volume = {9},
doi = {10.3389/fcvm.2022.1106845}
}
EUVIMED