EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY-NC 4.0

Totally Endoscopic Aortic Valve Replacement With Triangulated Suturing: How to Do It

Gianpiero Buttiglione iD, Can Gollmann-Tepeköylü, Lukas Stastny iD, Judith Martini, Daniel Höfer, Michael Grimm, Nikolaos Bonaros iD

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery · 2025-07 · 20 (4) · 406-409

DOI: 10.1177/15569845251344614 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, online erschienen am 09.06.2025. Verfasst von Gianpiero Buttiglione und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, IRCCS Policlinico San Donato, Milan, Italy. Hauptthemen laut MEDLINE: Heart Valve Prosthesis Implantation, Suture Techniques, Aortic Valve, Endoscopy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 7 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the evolving landscape of endoscopic aortic valve replacement (AVR), the alignment of instruments is crucial for overcoming difficulties related to the narrow aortic space. Here, we describe a technique of lateral suturing based on the principle of instrument triangulation, which allows perpendicular stiches to the aortic annulus like an open aortic valve procedure. This technique facilitates endoscopic AVR, performed through a 3 cm long right anterolateral mini-thoracotomy without rib retraction using a 3-dimensional endoscope and femoro-femoral cardiopulmonary bypass. Our approach uses a more lateral positioning of the vent and the transthoracic clamp as well as the addition of a single lateral port, which allows optimal angulation of the instruments to the aortic annulus and the ascending aorta. This technique facilitates endoscopic suturing without the use of automated devices through a transverse aortotomy. Annular sutures are placed in a perpendicular way in the aortic annulus by avoiding challenging “hook” stitches. In this case, we use an additional 10 mm port in the fourth right intercostal space through a small periareolar incision. With this technique, it is possible to implant any type of aortic prosthesis, either biological or mechanical.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve Prosthesis ImplantationSuture TechniquesAortic ValveEndoscopyHumansThoracotomy

Stichwörter der Autor:innen

aortic valve replacementendoscopic surgeryminimally invasive aortic valve surgerytriangulated suturing

Autor:innen und Institutionen

  • Department of Cardiac Surgery, IRCCS Policlinico San Donato, Milan, Italy.
  • Department of Cardiac Surgery, Medical University Innsbruck, Austria.

ORCID-Profile: Gianpiero Buttiglione, Lukas Stastny, Nikolaos Bonaros

Zitieren

APA

Buttiglione, G., Gollmann-Tepeköylü, C., Stastny, L., Martini, J., Höfer, D., Grimm, M., & Bonaros, N. (2025). Totally Endoscopic Aortic Valve Replacement With Triangulated Suturing: How to Do It. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 20(4), 406-409. https://doi.org/10.1177/15569845251344614

Vancouver

Buttiglione G, Gollmann-Tepeköylü C, Stastny L, Martini J, Höfer D, Grimm M, et al. Totally Endoscopic Aortic Valve Replacement With Triangulated Suturing: How to Do It. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 2025;20(4):406-409. doi:10.1177/15569845251344614

BibTeX
@article{Buttiglione2025,
  author = {Buttiglione, Gianpiero and Gollmann-Tepeköylü, Can and Stastny, Lukas and Martini, Judith and Höfer, Daniel and Grimm, Michael and Bonaros, Nikolaos},
  title = {Totally Endoscopic Aortic Valve Replacement With Triangulated Suturing: How to Do It},
  journal = {Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery},
  year = {2025},
  volume = {20},
  number = {4},
  pages = {406--409},
  doi = {10.1177/15569845251344614}
}
Kostenlos starten →