Modeling and Applicability of Nonlinear RDDS for Controlled Closing of 550 kV SF6 Circuit Breakers
Energies · 16.11.2026 · 19 (22) · 5509
DOI: 10.3390/en19225509 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 16.11.2026. Verfasst von Dehua Xiong und 2 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundamental Research Funds for the Central Universities, State Grid Shanghai Electric Power Company Science and Technology Project.
Abstract (Originalsprache)
In the controlled closing of high voltage circuit breakers, the electrical making instant depends on how dielectric strength changes as the contacts approach. For a 550 kV SF6 circuit breaker, scaled contact breakdown tests were conducted to investigate the variation of breakdown voltage with gap distance, while electric field calculations were used to determine the dielectric strength characteristic of the actual interrupter. This characteristic was combined with 50 measured closing trajectories to analyze the rate of decay of dielectric strength (RDDS). Constant, piecewise linear and nonlinear RDDS models were calibrated using phase scan data and evaluated against 17 independent rated 90° closing records without refitting. The results show that spatial variation in dielectric strength has a much greater influence on the calculated RDDS characteristic than variation in closing speed. Relative to the calculated reference, spatial linearization produced a voltage RMSE of 170.21 kV, compared with 3.85 kV when measured motion was replaced by constant speed. Under the healthy contact condition, the three calibrated models gave a maximum difference of approximately 0.11 ms in the calculated mechanical closing targets, although their voltage and time prediction errors showed different rankings. Comparisons across four contact erosion states showed that calculated targets for S0 and S1 were unchanged across the four tested continuation rules, whereas S2 and S3 targets and some peak-closing method selections depended on the extrapolation assumption. The results indicate that RDDS model selection should account for contact condition, operating range, data coverage, and extrapolation assumptions rather than fitting accuracy alone.
Förderung
- Fundamental Research Funds for the Central Universities
- State Grid Shanghai Electric Power Company Science and Technology Project
Zitieren
APA
Xiong, D., Duan, X., & Liao, M. (2026). Modeling and Applicability of Nonlinear RDDS for Controlled Closing of 550 kV SF6 Circuit Breakers. Energies, 19(22), 5509. https://doi.org/10.3390/en19225509
Vancouver
Xiong D, Duan X, Liao M. Modeling and Applicability of Nonlinear RDDS for Controlled Closing of 550 kV SF6 Circuit Breakers. Energies. 2026;19(22):5509. doi:10.3390/en19225509
BibTeX
@article{Xiong2026,
author = {Xiong, Dehua and Duan, Xiongying and Liao, Minfu},
title = {Modeling and Applicability of Nonlinear RDDS for Controlled Closing of 550 kV SF6 Circuit Breakers},
journal = {Energies},
year = {2026},
volume = {19},
number = {22},
pages = {5509},
doi = {10.3390/en19225509}
}