Fachartikel in der Zeitschrift Sensors, online erschienen am 25.06.2025. Verfasst von Ningfang Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical & Information Engineering, Changsha University of Science & Technology, Changsha 410114, China. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of China, Natural Science Foundation of Hunan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the rapid advancement of digitalization and intelligence in power systems, SF6 high-voltage circuit breakers, as the core switching devices in power grid protection systems, have become critical components in high-voltage networks of 110 kV and above due to their superior insulation performance and exceptional arc-quenching capability. Their operational status directly impacts the reliability of power system protection. Therefore, real-time condition monitoring and accurate assessment of SF6 circuit breakers along with science-based maintenance strategies derived from evaluation results hold significant engineering value for ensuring secure and stable grid operation and preventing major failures. In recent years, the frequency of extreme weather events has been increasing, necessitating a comprehensive consideration of both internal and external factors in the operational status prediction of SF6 high-voltage circuit breakers. To address this, we propose an operational status assessment model for SF6 high-voltage circuit breakers based on an Integrated Attribute-Weighted Risk Model Based on the Branch–Trunk Rule (IAR-BTR), which integrates internal and environmental influences. Firstly, to tackle the issues of incomplete data and feature imbalance caused by irrelevant attributes, this study employs missing value elimination (Drop method) on the fault record database. The selected dataset is then normalized according to the input feature matrix. Secondly, conventional risk factors are extracted using traditional association rule mining techniques. To improve the accuracy of these rules, the filtering thresholds and association metrics are refined based on seasonal distribution and the importance of time periods. This allows for the identification of spatiotemporally non-stationary factors that are strongly correlated with circuit breaker failures in low-probability seasonal conditions. Finally, a quantitative weighting method is developed for analyzing branch-trunk rules to accurately assess the impact of various factors on the overall stability of the circuit breaker. The DFP-Growth algorithm is applied to enhance the computational efficiency of the model. The case study results demonstrate that the proposed method achieves exceptional accuracy (95.78%) and precision (97.22%) and significantly improves the predictive performance of SF6 high-voltage circuit breaker operational condition assessments.

Schlagwörter

Stichwörter der Autor:innen

SF6 high-voltage circuit breakersoperational status assessmentquantitative weighting methodspatiotemporally non-stationary factors

Autor:innen und Institutionen

  • School of Electrical & Information Engineering, Changsha University of Science & Technology, Changsha 410114, China.
  • International College of Engineering, Changsha University of Science & Technology, Changsha 410114, China.

ORCID-Profile: Chenhao Sun

Förderung

  • Natural Science Foundation of China
  • Natural Science Foundation of Hunan

Zitieren

APA

Wang, N., Wang, Y., Zhang, Y., Tang, C., & Sun, C. (2025). An Operational Status Assessment Model for SF6 High-Voltage Circuit Breakers Based on IAR-BTR. Sensors, 25(13), 3960. https://doi.org/10.3390/s25133960

Vancouver

Wang N, Wang Y, Zhang Y, Tang C, Sun C. An Operational Status Assessment Model for SF6 High-Voltage Circuit Breakers Based on IAR-BTR. Sensors. 2025;25(13):3960. doi:10.3390/s25133960

BibTeX
@article{Wang2025,
  author = {Wang, Ningfang and Wang, Yujia and Zhang, Yifei and Tang, Ci and Sun, Chenhao},
  title = {An Operational Status Assessment Model for SF6 High-Voltage Circuit Breakers Based on IAR-BTR},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {13},
  pages = {3960},
  doi = {10.3390/s25133960}
}
Kostenlos starten →