Prediction of the Closing Time of UHV Disc Spring Hydraulic Operating Mechanism Circuit Breakers Considering Low-Cycle Fatigue
Processes · 15.04.2025 · 13 (4) · 1196
DOI: 10.3390/pr13041196 ↗Kurz gefasst
Fachartikel in der Zeitschrift Processes, online erschienen am 15.04.2025. Verfasst von Qi Long und 9 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Project of China Southern Power Grid, China Southern Power Grid.
Abstract (Originalsprache)
To address the issues of cumulative plastic deformation and low-cycle fatigue cracking in ultra-high voltage (UHV) disc spring hydraulic circuit breakers under long-term cyclic high-pressure loads, which lead to internal structural changes and affect closing time stability and phase-controlled closing accuracy, this paper proposes a closing time prediction model considering the low-cycle fatigue of the operating mechanism. First, a Simulink-based simulation model of the 550 kV disc spring hydraulic operating mechanism transmission system was developed to analyze the influence of structural parameter variations on closing time under no-load conditions. Then, an objective function for judging action time stability was constructed, and the stability and influence weights of each structural parameter were calculated under different mechanical dispersion requirements using a combination of adaptive surrogate models and directional importance sampling. Results show that critical parameters such as working cylinder inner diameter, working cylinder stroke, main valve stroke, and working cylinder rod diameter significantly affect closing time, contributing approximately 25%, 20%, 15%, and 10%, respectively. Finally, a dynamic-weighted closing time prediction model was designed based on different phase-controlled accuracy requirements. Compared with no-load closing tests, under mechanical dispersion conditions of ±1 ms, ±1.5 ms, and ±2 ms, the optimized model reduced maximum deviations by 12.8%, 20.4%, and 23.3%, and narrowed fluctuation ranges by 37%, 38.3%, and 38.6%, respectively, significantly improving prediction accuracy. This work is supported by the Science and Technology Project of China Southern Power Grid (No.CGYKJXM20220346).
Förderung
- Science and Technology Project of China Southern Power Grid
- China Southern Power Grid
Zitieren
APA
Long, Q., Yang, X., Jiang, K., Li, W., Li, M., Hou, M., Peng, X., Huang, D., Xiong, D., & Duan, X. (2025). Prediction of the Closing Time of UHV Disc Spring Hydraulic Operating Mechanism Circuit Breakers Considering Low-Cycle Fatigue. Processes, 13(4), 1196. https://doi.org/10.3390/pr13041196
Vancouver
Long Q, Yang X, Jiang K, Li W, Li M, Hou M, et al. Prediction of the Closing Time of UHV Disc Spring Hydraulic Operating Mechanism Circuit Breakers Considering Low-Cycle Fatigue. Processes. 2025;13(4):1196. doi:10.3390/pr13041196
BibTeX
@article{Long2025,
author = {Long, Qi and Yang, Xu and Jiang, Keru and Li, Weiguo and Li, Mingyang and Hou, Mingchun and Peng, Xiang and Huang, Dachao and Xiong, Dehua and Duan, Xiongying},
title = {Prediction of the Closing Time of UHV Disc Spring Hydraulic Operating Mechanism Circuit Breakers Considering Low-Cycle Fatigue},
journal = {Processes},
year = {2025},
volume = {13},
number = {4},
pages = {1196},
doi = {10.3390/pr13041196}
}
EUVIMED