Particle Swarm-Based Active Power Command Correction Virtual Synchronous Generator Control for Inverters with Current Limiting Capability and Enhanced Transient Stability
Energies · 20.05.2026 · 19 (10) · 2460
DOI: 10.3390/en19102460 ↗Kurz gefasst
Fachartikel in der Zeitschrift Energies, online erschienen am 20.05.2026. Verfasst von Qiang Wang und 7 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Hebei Electric Power Company.
Abstract (Originalsprache)
When a fault occurs in the power grid to which the Virtual Synchronous Generator (VSG) is connected, it leads to overcurrent phenomena, which threatens the safety of the inverter and easily results in device damage. Although existing direct current limiting unit (CLU) control strategies can restrict the fault current, the input active power command far exceeds the power output, causing the virtual rotor to continuously accelerate. This leads to power angle divergence and a subsequent loss of synchronization. To address the conflict between direct current-limiting control and system transient stability, this paper proposes a control strategy based on the Particle Swarm Optimization (PSO) algorithm to modify the active power command, building upon existing direct current-limiting VSG control. During grid faults, the output current is constrained to its maximum value, leading to a reduction in the system’s output power. By leveraging the PSO algorithm, the proposed strategy decreases the active power command to minimize the power mismatch between the command and the output. This maximizes the system’s transient stability by minimizing the rotor acceleration torque and effectively suppressing excessive power angle deviation. Meanwhile, the active power command reduction is introduced as a penalty term to maximize the active power output capability during the fault period. Simulation results demonstrate that, compared to VSG with only direct current-limiting control, the proposed strategy significantly enhances the transient stability and transmission efficiency of the VSG under long-term fault conditions across various grid voltage sag scenarios. Furthermore, it ensures a seamless transition from the fault state to normal operation during short-term faults.
Förderung
- State Grid Hebei Electric Power Company
Zitieren
APA
Wang, Q., Shi, M., Lv, H., Zhang, F., Gao, Y., Lv, C., Yin, X., & Yan, J. (2026). Particle Swarm-Based Active Power Command Correction Virtual Synchronous Generator Control for Inverters with Current Limiting Capability and Enhanced Transient Stability. Energies, 19(10), 2460. https://doi.org/10.3390/en19102460
Vancouver
Wang Q, Shi M, Lv H, Zhang F, Gao Y, Lv C, et al. Particle Swarm-Based Active Power Command Correction Virtual Synchronous Generator Control for Inverters with Current Limiting Capability and Enhanced Transient Stability. Energies. 2026;19(10):2460. doi:10.3390/en19102460
BibTeX
@article{Wang2026,
author = {Wang, Qiang and Shi, Min and Lv, Hao and Zhang, Fei-Fei and Gao, Yan and Lv, Chen-Miao and Yin, Xiao-Qi and Yan, Juan},
title = {Particle Swarm-Based Active Power Command Correction Virtual Synchronous Generator Control for Inverters with Current Limiting Capability and Enhanced Transient Stability},
journal = {Energies},
year = {2026},
volume = {19},
number = {10},
pages = {2460},
doi = {10.3390/en19102460}
}