EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Vacuum Degree Monitoring of Distribution Class Vacuum Interrupter Using Non-Contact Coupling Capacitor Based on AC and DC Partial Discharge

Seungmin Bang, Chanyeol Ryu, Bang-Wook Lee

Energies · 2026-04-21 · 19 (8) · 2005

DOI: 10.3390/en19082005 ↗

At a glance

Journal article in Energies, published online on 2026-04-21. Written by Seungmin Bang and 2 co-authors. 31 references. The full text is freely available (open access, CC BY 4.0).

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Vacuum degree inside vacuum interrupter (VI) deteriorates due to cracks from long-term operation of VI, gas emitted from internal arc heat, leakage through the joint, etc. Partial discharge occurs between the two contacts inside the VI or between the contact and floating shield, which leads to dielectric breakdown and electrical accidents of high voltage apparatus. In this paper, the study on the vacuum degree monitoring of distribution class vacuum interrupter according to non-contact method of coupling capacitor based on partial discharge was performed. In order to monitor the partial discharge between two contacts inside VI with high accuracy, a partial discharge sensing electrode (PDDE) was designed using the 3D finite element method (FEM). In addition, after calculating the internal capacitance according to the structure and size characteristics inside VI, the capacity of the coupling capacitor to detect the signal was calculated. The partial discharge characteristics according to the vacuum degree were analyzed by applying PDDE and a coupling capacitor. As results, it was found that the partial discharge characteristics inside VI differ depending on the voltage type. In addition, it was confirmed that even if VI has the same internal structure and size, the partial discharge characteristics appear differently. Based on the experimental results, we proposed maintenance criteria for VI for each voltage type.

Cite

APA

Bang, S., Ryu, C., & Lee, B. (2026). Vacuum Degree Monitoring of Distribution Class Vacuum Interrupter Using Non-Contact Coupling Capacitor Based on AC and DC Partial Discharge. Energies, 19(8), 2005. https://doi.org/10.3390/en19082005

Vancouver

Bang S, Ryu C, Lee B. Vacuum Degree Monitoring of Distribution Class Vacuum Interrupter Using Non-Contact Coupling Capacitor Based on AC and DC Partial Discharge. Energies. 2026;19(8):2005. doi:10.3390/en19082005

BibTeX
@article{Bang2026,
  author = {Bang, Seungmin and Ryu, Chanyeol and Lee, Bang-Wook},
  title = {Vacuum Degree Monitoring of Distribution Class Vacuum Interrupter Using Non-Contact Coupling Capacitor Based on AC and DC Partial Discharge},
  journal = {Energies},
  year = {2026},
  volume = {19},
  number = {8},
  pages = {2005},
  doi = {10.3390/en19082005}
}
Start for free →