Kurz gefasst

Fachartikel in der Zeitschrift IEEJ Transactions on Electrical and Electronic Engineering, online erschienen am 10.09.2025. Verfasst von Can Ding und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 69 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As the core component of the vacuum arc extinguishing chamber, the structure and parameters of the contact are important factors affecting the breaking fault current capacity of the DC circuit breaker. This paper first introduces the commonly used transverse and longitudinal magnetic contact structures of vacuum interrupters at power frequency and correspondingly provides the magnetic field distribution generated by them. Then, the characteristics of vacuum arc extinguishing chamber arcing and breaking during the DC breaking process were analyzed; it was found that the magnetic field strength and distribution of existing power frequency contacts under high‐frequency current do not meet the DC operating conditions. Based on this, the design requirements for the contact structure under DC breaking conditions were proposed, and an example of contact design suitable for DC breaking conditions was provided. Finally, this article discusses and prospects the issues that need to be further studied in the design process of the contact structure of the vacuum interrupter of DC circuit breakers. This paper can provide a reference for the design of the contact structure of vacuum interrupters for DC interruptions. © 2025 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.

Zitieren

APA

Ding, C., Zhu, Q., & Tian, Y. (2026). Review on the Design of Vacuum Interrupter Contact Structure for DC Circuit Breakers. IEEJ Transactions on Electrical and Electronic Engineering, 21(4), 495-504. https://doi.org/10.1002/tee.70146

Vancouver

Ding C, Zhu Q, Tian Y. Review on the Design of Vacuum Interrupter Contact Structure for DC Circuit Breakers. IEEJ Transactions on Electrical and Electronic Engineering. 2026;21(4):495-504. doi:10.1002/tee.70146

BibTeX
@article{Ding2026,
  author = {Ding, Can and Zhu, Qingzhou and Tian, Yiting},
  title = {Review on the Design of Vacuum Interrupter Contact Structure for DC Circuit Breakers},
  journal = {IEEJ Transactions on Electrical and Electronic Engineering},
  year = {2026},
  volume = {21},
  number = {4},
  pages = {495--504},
  doi = {10.1002/tee.70146}
}
Kostenlos starten →