Transient Overvoltage Analysis and Insulation Coordination for an ±800 kV/8 GW MMC-Based Ultra-High-Voltage DC Transmission System
Electronics · 01.07.2026 · 15 (13) · 2859
DOI: 10.3390/electronics15132859 ↗Kurz gefasst
Fachartikel in der Zeitschrift Electronics, online erschienen am 01.07.2026. Verfasst von Xiaorui Liu und 11 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Power Engineering Consulting Group Co., Ltd..
Abstract (Originalsprache)
Facing the demand of long-distance, high-voltage and high-power transmission, the research on MMC-UHVDC (Modular Multilevel Converter based Ultra High Voltage Direct Current) has become a hot issue. This paper focuses on the ±800 kV/8 GW UHVDC transmission system to conduct simulation modelling and insulation coordination studies. First, broadband models of the main circuit and primary equipment are established to simulate and analyse the distribution characteristics of both switching and lightning transient overvoltages under typical faults. Second, based on the overvoltage severity at critical nodes, two surge arrester configuration schemes with distinct internal valve protection topologies are proposed. Finally, an Improved Fuzzy Analytic Hierarchy Process (FAHP) is introduced to perform a quantitative techno-economic evaluation of the comparative schemes. The results demonstrate that the optimised configuration successfully suppresses extreme overvoltages at vulnerable sub-module nodes, maintaining adequate insulation margins. These research findings provide a highly reliable mathematical framework and engineering reference for the safe design of UHVDC systems.
Förderung
- China Power Engineering Consulting Group Co., Ltd.
Zitieren
APA
Liu, X., Zhou, G., He, T., Ning, L., Zeng, W., Xia, L., Li, H., Wang, Q., Zhang, J., Fan, R., Liu, X., & Song, H. (2026). Transient Overvoltage Analysis and Insulation Coordination for an ±800 kV/8 GW MMC-Based Ultra-High-Voltage DC Transmission System. Electronics, 15(13), 2859. https://doi.org/10.3390/electronics15132859
Vancouver
Liu X, Zhou G, He T, Ning L, Zeng W, Xia L, et al. Transient Overvoltage Analysis and Insulation Coordination for an ±800 kV/8 GW MMC-Based Ultra-High-Voltage DC Transmission System. Electronics. 2026;15(13):2859. doi:10.3390/electronics15132859
BibTeX
@article{Liu2026,
author = {Liu, Xiaorui and Zhou, Guoliang and He, Tiantian and Ning, Lianhui and Zeng, Weiwen and Xia, Lingfeng and Li, Haoyuan and Wang, Qingxin and Zhang, Junyuan and Fan, Ruoxi and Liu, Xinliang and Song, Hanjin},
title = {Transient Overvoltage Analysis and Insulation Coordination for an ±800 kV/8 GW MMC-Based Ultra-High-Voltage DC Transmission System},
journal = {Electronics},
year = {2026},
volume = {15},
number = {13},
pages = {2859},
doi = {10.3390/electronics15132859}
}
EUVIMED