Journal article in Electronics, published online on 2026-07-01. Written by Xiaorui Liu and 11 co-authors. 23 references. The full text is freely available (open access, CC BY 4.0). Funded by: China Power Engineering Consulting Group Co., Ltd..

AbstraktBibliografické údajeCiteRelated studies

Abstract (original language)

Facing the demand of long-distance, high-voltage and high-power transmission, the research on MMC-UHVDC (Modular Multilevel Converter based Ultra High Voltage Direct Current) has become a hot issue. This paper focuses on the ±800 kV/8 GW UHVDC transmission system to conduct simulation modelling and insulation coordination studies. First, broadband models of the main circuit and primary equipment are established to simulate and analyse the distribution characteristics of both switching and lightning transient overvoltages under typical faults. Second, based on the overvoltage severity at critical nodes, two surge arrester configuration schemes with distinct internal valve protection topologies are proposed. Finally, an Improved Fuzzy Analytic Hierarchy Process (FAHP) is introduced to perform a quantitative techno-economic evaluation of the comparative schemes. The results demonstrate that the optimised configuration successfully suppresses extreme overvoltages at vulnerable sub-module nodes, maintaining adequate insulation margins. These research findings provide a highly reliable mathematical framework and engineering reference for the safe design of UHVDC systems.

Funding

  • China Power Engineering Consulting Group Co., Ltd.

Cite

APA

Liu, X., Zhou, G., He, T., Ning, L., Zeng, W., Xia, L., Li, H., Wang, Q., Zhang, J., Fan, R., Liu, X., & Song, H. (2026). Transient Overvoltage Analysis and Insulation Coordination for an ±800 kV/8 GW MMC-Based Ultra-High-Voltage DC Transmission System. Electronics, 15(13), 2859. https://doi.org/10.3390/electronics15132859

Vancouver

Liu X, Zhou G, He T, Ning L, Zeng W, Xia L, et al. Transient Overvoltage Analysis and Insulation Coordination for an ±800 kV/8 GW MMC-Based Ultra-High-Voltage DC Transmission System. Electronics. 2026;15(13):2859. doi:10.3390/electronics15132859

BibTeX
@article{Liu2026,
  author = {Liu, Xiaorui and Zhou, Guoliang and He, Tiantian and Ning, Lianhui and Zeng, Weiwen and Xia, Lingfeng and Li, Haoyuan and Wang, Qingxin and Zhang, Junyuan and Fan, Ruoxi and Liu, Xinliang and Song, Hanjin},
  title = {Transient Overvoltage Analysis and Insulation Coordination for an ±800 kV/8 GW MMC-Based Ultra-High-Voltage DC Transmission System},
  journal = {Electronics},
  year = {2026},
  volume = {15},
  number = {13},
  pages = {2859},
  doi = {10.3390/electronics15132859}
}
Start for free →