Mechanical Properties of Dental Occlusal Splint Materials After Accelerated Aging in Artificial Saliva: An In Vitro Study
Dentistry Journal · 04.08.2026 · 14 (8) · 478
DOI: 10.3390/dj14080478 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentistry Journal, online erschienen am 04.08.2026. Verfasst von Iulia Karla Nică und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthetics, Faculty of Dentistry, "Carol Davila" University of Medicine and Pharmacy, 020021 Bucharest, Romania. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Occlusal splints are exposed to prolonged intraoral conditions, including saliva, temperature fluctuations, and mechanical loading, which may alter their mechanical performance over time. The increasing use of SLA 3D-printed photopolymer resins for splint fabrication has introduced new materials whose aging-related mechanical stability remains insufficiently characterized.
Objectives
This in vitro study evaluated the effects of accelerated aging in artificial saliva on the Shore D hardness and flexural properties, including flexural modulus, flexural strength, and strain at failure, of four polymeric materials used for occlusal splint fabrication: a thermoformed PETG material (Duran, C), a milled PMMA (Bilkim Polywax, F), and two SLA-printed photopolymer resins (HARZ Labs Dental Clear, H; NextDent Ortho Rigid, N). Materials and Methods: Eighty rectangular specimens (n = 20/material) were fabricated following ASTM D790 and subjected to accelerated aging in Fusayama artificial saliva at 60 °C for 24, 48, and 72 h. Shore D hardness was assessed first as a non-destructive measurement, followed by three-point bending tests yielding flexural modulus, flexural strength, and strain at failure. Data were analyzed using one-way ANOVA and post hoc multiple comparisons at a significance level of α = 0.05.
Results
Aging effects were material-dependent. Duran (C) showed no statistically significant changes in Shore D hardness (p = 0.651) and only non-progressive variations in flexural behavior. Bilkim Polywax (F) exhibited a significant hardness reduction at 48 h (p = 0.004) and selective changes in flexural strength at 72 h. HARZ Labs Dental Clear (H) showed the most severe and progressive deterioration, with significant reductions in all evaluated parameters, including hardness decreases of up to 5.8% and flexural modulus reductions exceeding 49%. NextDent Ortho Rigid (N) demonstrated an initial hardness decrease followed by stabilization, with a significant reduction in flexural modulus at 72 h.
Conclusions
Under the accelerated hydrothermal aging conditions employed in this study, the two investigated SLA-printed photopolymer resins (HARZ Labs Dental Clear and NextDent Ortho Rigid) exhibited greater mechanical deterioration than the tested thermoformed PETG and milled PMMA materials. These findings are limited to the investigated materials, standardized rectangular specimens, and the specific accelerated aging protocol used in this study. Among the tested materials, thermoformed PETG demonstrated the greatest mechanical stability. Material-specific evaluation of aging resistance remains advisable before routine clinical application, particularly for digitally fabricated occlusal splints intended for prolonged intraoral service.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthetics, Faculty of Dentistry, "Carol Davila" University of Medicine and Pharmacy, 020021 Bucharest, Romania.
- Discipline of Dental Prosthetics Technology, Faculty of Dentistry, "Carol Davila" University of Medicine and Pharmacy, Dionisie Lupu Street, No. 37, District 2, 020021 Bucharest, Romania.
- Department of Metallic Materials Science, Physical Metallurgy, University Politehnica of Bucharest, 313 Splaiul Independentei, J Building, 060042 Bucharest, Romania.
- Eastman Dental Institute, Rockefeller Building, 21 University Street, London WC1E 6DGL, UK.
- Discipline of Organization, Professional Legislation and Dental Office Management, "Carol Davila" University of Medicine and Pharmacy, Dionisie Lupu Street, No. 37, District 2, 020021 Bucharest, Romania.
ORCID-Profile: Lucian Toma Ciocan, Vlad Gabriel Vasilescu, Robert Cătălin Ciocoiu, Andreea Mihaela Custură, Alexandru Titus Farcașiu
Zitieren
APA
Nică, I. K., Ciocan, L. T., Vasilescu, V. G., Ciocoiu, R. C., Foschi, F., Custură, A. M., Radu, E. A., Farcașiu, A. T., Pițuru, S. M., & Imre, M. (2026). Mechanical Properties of Dental Occlusal Splint Materials After Accelerated Aging in Artificial Saliva: An In Vitro Study. Dentistry Journal, 14(8), 478. https://doi.org/10.3390/dj14080478
Vancouver
Nică IK, Ciocan LT, Vasilescu VG, Ciocoiu RC, Foschi F, Custură AM, et al. Mechanical Properties of Dental Occlusal Splint Materials After Accelerated Aging in Artificial Saliva: An In Vitro Study. Dentistry Journal. 2026;14(8):478. doi:10.3390/dj14080478
BibTeX
@article{Nic2026,
author = {Nică, Iulia Karla and Ciocan, Lucian Toma and Vasilescu, Vlad Gabriel and Ciocoiu, Robert Cătălin and Foschi, Federico and Custură, Andreea Mihaela and Radu, Elisei Adelin and Farcașiu, Alexandru Titus and Pițuru, Silviu Mirel and Imre, Marina},
title = {Mechanical Properties of Dental Occlusal Splint Materials After Accelerated Aging in Artificial Saliva: An In Vitro Study},
journal = {Dentistry Journal},
year = {2026},
volume = {14},
number = {8},
pages = {478},
doi = {10.3390/dj14080478}
}
EUVIMED