Dimensional Accuracy and Short-Term Stability of Orthodontic Resin-Printed Models: A Closed Dental System Compared with Commercial Desktop Workflows
Dentistry Journal · 09.04.2026 · 14 (4) · 220
DOI: 10.3390/dj14040220 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentistry Journal, online erschienen am 09.04.2026. Verfasst von Pilar España-Pamplona und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dentistry, Universidad Europea de Valencia, 46010 Valencia, Spain. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: Resin 3D printing is widely used to fabricate orthodontic diagnostic models, but the practical performance of commercial desktop workflows compared to dental-certified workflows is still debated. This study compared the dimensional accuracy and 7-day stability of maxillary orthodontic models printed from the same master STL file using a dental-certified workflow versus two commercial desktop workflows.
Methods
An ISO 20896-1:2019-based reference cast with four 6 mm calibration spheres was used to generate a master STL file. Fifteen models were printed (n = 5 per workflow) using Primeprint™ (dental-certified workflow) and two commercial desktop printers (Anycubic Photon Mono M5s; Phrozen Sonic Mighty 14K REVO). The models were digitized at baseline (T0, ≤48 h) and after 7 days (T7) using a laboratory scanner. Surface superimposition in CloudCompare® calculated the RMS (root mean square) surface deviation and mean signed deviation, and two calibrated operators performed independent extractions.
Results
The mean RMS deviations were 0.05), and the inter-operator agreement was excellent (ICC 0.991–0.999).
Conclusions
Under the tested workflows, dental-certified and commercial desktop resin printing produced orthodontic models with a comparable global surface accuracy and short-term dimensional stability.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Dentistry, Universidad Europea de Valencia, 46010 Valencia, Spain.
- Department of Chemical Science and Technologies, Materials for Sustainable Development-Dentistry, University of Rome Tor Vergata, 00133 Rome, Italy.
- Department of Surgery, Universidad de Salamanca, 37007 Salamanca, Spain.
- Department of Biomedical, Surgical, and Dental Science, University of Milan, 20122 Milan, Italy.
ORCID-Profile: Pilar España-Pamplona, Davide Gentile, Adrian Curto-Aguilera, Riccardo Aiuto, Milagros Adobes-Martin, Daniele Garcovich
Zitieren
APA
España-Pamplona, P., Gentile, D., Curto-Aguilera, A., Aiuto, R., Adobes-Martin, M., & Garcovich, D. (2026). Dimensional Accuracy and Short-Term Stability of Orthodontic Resin-Printed Models: A Closed Dental System Compared with Commercial Desktop Workflows. Dentistry Journal, 14(4), 220. https://doi.org/10.3390/dj14040220
Vancouver
España-Pamplona P, Gentile D, Curto-Aguilera A, Aiuto R, Adobes-Martin M, Garcovich D. Dimensional Accuracy and Short-Term Stability of Orthodontic Resin-Printed Models: A Closed Dental System Compared with Commercial Desktop Workflows. Dentistry Journal. 2026;14(4):220. doi:10.3390/dj14040220
BibTeX
@article{EspaaPamplona2026,
author = {España-Pamplona, Pilar and Gentile, Davide and Curto-Aguilera, Adrian and Aiuto, Riccardo and Adobes-Martin, Milagros and Garcovich, Daniele},
title = {Dimensional Accuracy and Short-Term Stability of Orthodontic Resin-Printed Models: A Closed Dental System Compared with Commercial Desktop Workflows},
journal = {Dentistry Journal},
year = {2026},
volume = {14},
number = {4},
pages = {220},
doi = {10.3390/dj14040220}
}
EUVIMED