Fachartikel in der Zeitschrift Diagnostics, online erschienen am 11.09.2024. Verfasst von Flaminia Tomassetti und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Experimental Medicine, University of Rome Tor Vergata, Via Montpellier 1, 00133 Rome, Italy. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Erythrocyte Sedimentation Rate (ESR) is an easy test used to diagnose and monitor inflammatory and infectious diseases. The aim of this study was the evaluation of the performance of three ESR automated analyzers, VES-MATIC 5, CUBE 30 TOUCH, and MINI-CUBE, involving four Italian polyclinics in Rome, Siena, Como, and Arezzo, as well as inter-site variability assessment to detect possible device-dependent and operator-dependent influences.
Methods
Accuracy analysis was carried out by analyzing the same samples with all three instruments and comparing them with the Westergren method. Precision was assessed with quality control material through intra-run and inter-run precision. Repeatability was estimated by reanalyzing fresh blood samples belonging to three ESR ranges (low, intermediate, and high) six times.
Results
The results showed a strong correlation (Spearman coefficients R2) between the manual method and VES-MATIC 5 (0.978), CUBE 30 TOUCH (0.981), and MINI-CUBE (0.974). The accuracy of all clinics was excellent, with coefficients of variation (CVs) of less than 10% for all instruments. Repeatability confirmed an excellent level for all ESR ranges, with CVs below 10%.
Conclusions
The study proved that all three automated instruments offer optimal performance for accuracy and precision and are suitable for both large and small facilities without influences of the laboratory environment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Experimental Medicine, University of Rome Tor Vergata, Via Montpellier 1, 00133 Rome, Italy.
- Department of Laboratory Medicine, Tor Vergata University Hospital, Viale Oxford 81, 00133 Rome, Italy.
- Clinical Pathology and Microbiology Unit, Laboratory Analysis, ASST Lariana, Hospital Sant'Anna, 22100 Como, Italy.
- Department of Translational Medical Sciences, University of Naples "Federico II", 80126 Naples, Italy.
- Research and Development Department, DIESSE Diagnostica Senese S.p.A., Monteriggioni, 53035 Siena, Italy.
- Clinical Pathology Unit, Innovation, Experimentation and Clinical and Translational Research Department, University Hospital of S. Maria alle Scotte of Siena, Viale Mario Bracci 16, 53100 Siena, Italy.
ORCID-Profile: Flaminia Tomassetti, Fabio Bertani, Daniela Diamanti, Maria Lorubbio, Agostino Ognibene, Eleonora Nicolai, Martina Pelagalli, Carolina Pieroni, Massimo Pieri
Zitieren
APA
Tomassetti, F., Calabrese, C., Bertani, F., Cennamo, M., Diamanti, D., Giovannelli, A., Guerranti, R., Leoncini, R., Lorubbio, M., Ognibene, A., Nicolai, E., Pelagalli, M., Pieroni, C., Bernardini, S., & Pieri, M. (2024). Performance Evaluation of Automated Erythrocyte Sedimentation Rate (ESR) Analyzers in a Multicentric Study. Diagnostics, 14(18), 2011. https://doi.org/10.3390/diagnostics14182011
Vancouver
Tomassetti F, Calabrese C, Bertani F, Cennamo M, Diamanti D, Giovannelli A, et al. Performance Evaluation of Automated Erythrocyte Sedimentation Rate (ESR) Analyzers in a Multicentric Study. Diagnostics. 2024;14(18):2011. doi:10.3390/diagnostics14182011
BibTeX
@article{Tomassetti2024,
author = {Tomassetti, Flaminia and Calabrese, Cinzia and Bertani, Fabio and Cennamo, Michele and Diamanti, Daniela and Giovannelli, Alfredo and Guerranti, Roberto and Leoncini, Roberto and Lorubbio, Maria and Ognibene, Agostino and Nicolai, Eleonora and Pelagalli, Martina and Pieroni, Carolina and Bernardini, Sergio and Pieri, Massimo},
title = {Performance Evaluation of Automated Erythrocyte Sedimentation Rate (ESR) Analyzers in a Multicentric Study},
journal = {Diagnostics},
year = {2024},
volume = {14},
number = {18},
pages = {2011},
doi = {10.3390/diagnostics14182011}
}
EUVIMED