Fachartikel in der Zeitschrift Diagnostics, online erschienen am 24.07.2024. Verfasst von Thomas Lund Andersen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital-Rigshospitalet, 2100 Copenhagen, Denmark. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The accurate estimation of the tracer arterial blood concentration is crucial for reliable quantitative kinetic analysis in PET. In the current work, we demonstrate the automatic extraction of an image-derived input function (IDIF) from a CT AI-based aorta segmentation subsequently resliced to a dynamic PET series acquired on a Siemens Vision Quadra long-axial field of view scanner in 10 human subjects scanned with [15O]H2O. We demonstrate that the extracted IDIF is quantitative and in excellent agreement with a delay- and dispersion-corrected sampled arterial input function (AIF). Perfusion maps in the brain are calculated and compared from the IDIF and AIF, respectively, showed a high degree of correlation. The results demonstrate the possibility of defining a quantitatively correct IDIF compared with AIFs from the new-generation high-sensitivity and high-time-resolution long-axial field-of-view PET/CT scanners.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital-Rigshospitalet, 2100 Copenhagen, Denmark.
- Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, 2200 Copenhagen, Denmark.
- Department of Neurology, Copenhagen University Hospital, Bispebjerg, 2400 Copenhagen, Denmark.
- Functional Imaging Unit, Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital-Rigshospitalet, 2600 Copenhagen, Denmark.
ORCID-Profile: Thomas Lund Andersen, Flemming Littrup Andersen, Ian Law, Ulrich Lindberg
Zitieren
APA
Andersen, T. L., Andersen, F. L., Haddock, B., Rosenbaum, S., Larsson, H. B. W., Law, I., & Lindberg, U. (2024). Automated Quantitative Image-Derived Input Function for the Estimation of Cerebral Blood Flow Using Oxygen-15-Labelled Water on a Long-Axial Field-of-View PET/CT Scanner. Diagnostics, 14(15), 1590. https://doi.org/10.3390/diagnostics14151590
Vancouver
Andersen TL, Andersen FL, Haddock B, Rosenbaum S, Larsson HBW, Law I, et al. Automated Quantitative Image-Derived Input Function for the Estimation of Cerebral Blood Flow Using Oxygen-15-Labelled Water on a Long-Axial Field-of-View PET/CT Scanner. Diagnostics. 2024;14(15):1590. doi:10.3390/diagnostics14151590
BibTeX
@article{Andersen2024,
author = {Andersen, Thomas Lund and Andersen, Flemming Littrup and Haddock, Bryan and Rosenbaum, Sverre and Larsson, Henrik Bo Wiberg and Law, Ian and Lindberg, Ulrich},
title = {Automated Quantitative Image-Derived Input Function for the Estimation of Cerebral Blood Flow Using Oxygen-15-Labelled Water on a Long-Axial Field-of-View PET/CT Scanner},
journal = {Diagnostics},
year = {2024},
volume = {14},
number = {15},
pages = {1590},
doi = {10.3390/diagnostics14151590}
}
EUVIMED