EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Long Axial Field of View PET

Faraz Farhadi, Eren Veziroglu, Jayasai Rajagopal, Nadine Hoyek, Eliot Siegel

Radiologic Clinics of North America · 2026-11 · 64 (6) · 1145-1165

DOI: 10.1016/j.rcl.2026.08.010 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Radiologic Clinics of North America, 2026-11. Verfasst von Faraz Farhadi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; Institute of Nuclear Medicine, Bethesda, MD, USA. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Positron-Emission Tomography. Die Arbeit nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Long axial field-of-view (LAFOV) PET/CT represents a major hardware evolution that expands detector coverage to dramatically increase geometric sensitivity. This amplified signal enables significantly shorter acquisitions, reduced administered radiotracer dose, improved lesion conspicuity, and delayed or low-count imaging. Rather than representing distinct platforms, extended-AFOV and long-AFOV systems exist along a continuum extending from conventional short-axis scanners. Both configurations share substantial functional overlap, driving profound workflow and dose-reduction benefits while supporting advanced dynamic and multiparametric protocols. For radiologists, maximizing this technology requires transitioning from static image assessment to managing complex quantitative data, fundamentally advancing molecular imaging across diverse medical specialties.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron Emission Tomography Computed TomographyPositron-Emission TomographyHumansSensitivity and SpecificityRadiation Dosage

Stichwörter der Autor:innen

Dose reductionDynamic PETExtended axial field-of-view PET/CTLong axial field-of-view PET/CTPET sensitivityParametric imagingTime-of-flight PETTotal-body PET

Autor:innen und Institutionen

  • Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; Institute of Nuclear Medicine, Bethesda, MD, USA.
  • Division of Molecular Imaging and Therapeutics, Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, USA.
  • Oak Ridge National Laboratory, Oak Ridge, TN, USA.
  • Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD, USA.
  • Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD, USA. Electronic address: esiegel@unithera.com.

Zitieren

APA

Farhadi, F., Veziroglu, E., Rajagopal, J., Hoyek, N., & Siegel, E. (2026). Long Axial Field of View PET. Radiologic Clinics of North America, 64(6), 1145-1165. https://doi.org/10.1016/j.rcl.2026.08.010

Vancouver

Farhadi F, Veziroglu E, Rajagopal J, Hoyek N, Siegel E. Long Axial Field of View PET. Radiologic Clinics of North America. 2026;64(6):1145-1165. doi:10.1016/j.rcl.2026.08.010

BibTeX
@article{Farhadi2026,
  author = {Farhadi, Faraz and Veziroglu, Eren and Rajagopal, Jayasai and Hoyek, Nadine and Siegel, Eliot},
  title = {Long Axial Field of View PET},
  journal = {Radiologic Clinics of North America},
  year = {2026},
  volume = {64},
  number = {6},
  pages = {1145--1165},
  doi = {10.1016/j.rcl.2026.08.010}
}
Kostenlos starten →