Evaluation of Whole Brain Intravoxel Incoherent Motion (IVIM) Imaging
Diagnostics · 20.03.2024 · 14 (6) · 653
DOI: 10.3390/diagnostics14060653 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 20.03.2024. Verfasst von Kamil Lipiński und 1 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Radioelectronics and Multimedia Technology, Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiej…. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Center, Polish National Science Centre.
Abstract (Originalsprache)
Intravoxel Incoherent Motion (IVIM) imaging provides non-invasive perfusion measurements, eliminating the need for contrast agents. This work explores the feasibility of IVIM imaging in whole brain perfusion studies, where an isotropic 1 mm voxel is widely accepted as a standard. This study follows the validity of a time-limited, precise, segmentation-ready whole-brain IVIM protocol suitable for clinical reality. To assess the influence of SNR on the estimation of S0, f, D*, and D IVIM parameters, a series of measurements and simulations were performed in MATLAB for the following three estimation techniques: segmented grid search, segmented curve fitting, and one-step curve fitting, utilizing known “ground truth” and noised data. Scanner-specific SNR was estimated based on a healthy subject IVIM MRI study in a 3T scanner. Measurements were conducted for 25.6 × 25.6 × 14.4 cm FOV with a 256 × 256 in-plane resolution and 72 slices, resulting in 1 × 1 × 2 mm voxel size. Simulations were performed for 36 SNR levels around the measured SNR value. For a single voxel grid, the search algorithm mean relative error Ŝ0, f^, D^*, and D^ of at the expected SNR level were 5.00%, 81.91%, 76.31%, and 18.34%, respectively. Analysis has shown that high-resolution IVIM imaging is possible, although there is significant variation in both accuracy and precision, depending on SNR and the chosen estimation method.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Radioelectronics and Multimedia Technology, Faculty of Electronics and Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland.
ORCID-Profile: Kamil Lipiński, Piotr Bogorodzki
Förderung
- National Science Center
- Polish National Science Centre
Zitieren
APA
Lipiński, K., & Bogorodzki, P. (2024). Evaluation of Whole Brain Intravoxel Incoherent Motion (IVIM) Imaging. Diagnostics, 14(6), 653. https://doi.org/10.3390/diagnostics14060653
Vancouver
Lipiński K, Bogorodzki P. Evaluation of Whole Brain Intravoxel Incoherent Motion (IVIM) Imaging. Diagnostics. 2024;14(6):653. doi:10.3390/diagnostics14060653
BibTeX
@article{Lipiski2024,
author = {Lipiński, Kamil and Bogorodzki, Piotr},
title = {Evaluation of Whole Brain Intravoxel Incoherent Motion (IVIM) Imaging},
journal = {Diagnostics},
year = {2024},
volume = {14},
number = {6},
pages = {653},
doi = {10.3390/diagnostics14060653}
}