A theoretical interpretation of diffusion weighted and intravoxel incoherent motion imaging for cerebrospinal fluid flow
Magnetic Resonance in Medicine · 2026-01 · 95 (1) · 628-636
DOI: 10.1002/mrm.70062 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 04.09.2025. Verfasst von Tomohiro Otani und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Science and Bioengineering, The University of Osaka Graduate School of Engineering Science, Osaka, Japan. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Cerebrospinal Fluid, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education, Culture, Sports, Science and Technology, Nakatani Foundation for Advancement of Measuring Technologies in Biomedical Engineering, Japan Society for the Promotion of Science.
Abstract (Originalsprache)
Purpose
Diffusion‐weighted imaging (DWI) and intravoxel incoherent motion (IVIM) imaging are well‐established approaches for evaluating cerebrospinal fluid (CSF) flow in subarachnoid and perivascular spaces, and have recently been applied to study ventricular CSF flow. However, DWI does not directly measure flow velocity, and the physical implications of DWI measurements are unclear. This study aimed to provide a theoretical interpretation of the DWI and IVIM imaging of CSF flow velocity fields. Theory The general semi‐analytical form of the signal attenuations caused by fluid flow and the resultant apparent diffusion coefficient were derived from the Bloch–Torrey equation for arbitrary values.
Methods
The fundamental properties of the signal attenuation in laminar flow velocity fields were investigated. A Monte Carlo simulation of the IVIM parameter estimation was performed based on these signal attenuations, taking background noise into consideration.
Results
The developed theoretical framework indicates that signal attenuations in DWI detect intravoxel flow velocity standard deviations ranging from approximately 0.1 to 10 mm/s within the range of practical scan parameter settings. The lower bounds of the DWI flow profiles appeared where the flow effect was an order of magnitude lower than the molecular diffusion effects, even when increased. The IVIM fitting parameters reflected the flow effects of the signal attenuations despite an inconsistency with the original IVIM model assumptions.
Conclusion
The physical implications of signal attenuation in DWI have been theoretically clarified. This framework provides a useful basis for understanding CSF flow dynamics and considering appropriate imaging settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Science and Bioengineering, The University of Osaka Graduate School of Engineering Science, Osaka, Japan.
- Department of Diagnostic Imaging, Hokkaido University Graduate School of Medicine, Hokkaido, Japan.
- Department of Neurosurgery, Nagoya City University Graduate School of Medical Science, Aichi, Japan.
- Interfaculty Initiative in Information Studies/Institute of Industrial Science, The University of Tokyo, Tokyo, Japan.
- Department of Radiology, Shiga University of Medical Science, Shiga, Japan.
ORCID-Profile: Tomohiro Otani, Yoshitaka Bito, Shigeki Yamada, Yoshiyuki Watanabe, Shigeo Wada
Förderung
- Ministry of Education, Culture, Sports, Science and Technology
- Nakatani Foundation for Advancement of Measuring Technologies in Biomedical Engineering
- Japan Society for the Promotion of Science
Zitieren
APA
Otani, T., Bito, Y., Yamada, S., Watanabe, Y., & Wada, S. (2026). A theoretical interpretation of diffusion weighted and intravoxel incoherent motion imaging for cerebrospinal fluid flow. Magnetic Resonance in Medicine, 95(1), 628-636. https://doi.org/10.1002/mrm.70062
Vancouver
Otani T, Bito Y, Yamada S, Watanabe Y, Wada S. A theoretical interpretation of diffusion weighted and intravoxel incoherent motion imaging for cerebrospinal fluid flow. Magnetic Resonance in Medicine. 2026;95(1):628-636. doi:10.1002/mrm.70062
BibTeX
@article{Otani2026,
author = {Otani, Tomohiro and Bito, Yoshitaka and Yamada, Shigeki and Watanabe, Yoshiyuki and Wada, Shigeo},
title = {A theoretical interpretation of diffusion weighted and intravoxel incoherent motion imaging for cerebrospinal fluid flow},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {95},
number = {1},
pages = {628--636},
doi = {10.1002/mrm.70062}
}
EUVIMED