Estimating Local Diagnostic Reference Levels for Mammography in Dubai
Diagnostics · 20.12.2023 · 14 (1) · 8
DOI: 10.3390/diagnostics14010008 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diagnostics, online erschienen am 20.12.2023. Verfasst von Kaltham Abdulwahid Noor und 4 weiteren Autor:innen. Beteiligte Einrichtung: Dubai Health Academic Corporate, Radiology Department, Rashid Hospital, Dubai 00971, United Arab Emirates. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Geran Rangsangan Penyelidikan FSK.
Abstract (Originalsprache)
As the total volume of mammograms in Dubai is increasing consistently, it is crucial to focus on the process of dose optimization by determining dose reference levels for such sensitive radiographic examinations as mammography. This work aimed to determine local diagnostic reference levels (DRLs) for mammography procedures in Dubai at different ranges of breast thickness. A total of 2599 anonymized mammograms were randomly retrieved from a central dose survey database. Mammographic cases for screening women aged from 40 to 69 years were included, while cases of breast implants and breast thickness outside the range of 20–100 mm were excluded. Mean, median, and 75 percentiles were obtained for the mean glandular dose (MGD) distribution of each mammography projection for all compressed breast thickness (CBT) ranges. The local DRLs for mammography in Dubai were found to be between 0.80 mGy and 0.82 mGy for the craniocaudal (CC) projection and between 0.89 mGy and 0.971.8 mGy for the mediolateral oblique (MLO) projection. Local DRLs were proposed according to different breast thicknesses, starting from 20 to 100 mm. All groups of CBT showed a slight difference in MGD values, with higher values in MLO views rather than CC views. The local DRLs in this study were lower than some other Middle Eastern countries and lower than the standard reference levels reported by the International Atomic Energy Agency (IAEA) at 3 mGy/view.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Dubai Health Academic Corporate, Radiology Department, Rashid Hospital, Dubai 00971, United Arab Emirates.
- Center of Diagnostic, Therapeutic and Investigative Studies (CODTIS), Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur 56000, Malaysia.
- Department of Physics, Faculty of Science, University Putra Malaysia, Serdang 43400, Malaysia.
- SEHA, Medical Physics Department, Al Ain Hospital, Abu Dhabi 80050, United Arab Emirates.
ORCID-Profile: Norhashimah Mohd Norsuddin, Muhammad Khalis Abdul Karim
Förderung
- Geran Rangsangan Penyelidikan FSK
Zitieren
APA
Abdulwahid Noor, K., Mohd Norsuddin, N., Abdul Karim, M. K., Che Isa, I. N., & Alshamsi, W. (2023). Estimating Local Diagnostic Reference Levels for Mammography in Dubai. Diagnostics, 14(1), 8. https://doi.org/10.3390/diagnostics14010008
Vancouver
Abdulwahid Noor K, Mohd Norsuddin N, Abdul Karim MK, Che Isa IN, Alshamsi W. Estimating Local Diagnostic Reference Levels for Mammography in Dubai. Diagnostics. 2023;14(1):8. doi:10.3390/diagnostics14010008
BibTeX
@article{AbdulwahidNoor2023,
author = {Abdulwahid Noor, Kaltham and Mohd Norsuddin, Norhashimah and Abdul Karim, Muhammad Khalis and Che Isa, Iza Nurzawani and Alshamsi, Wadha},
title = {Estimating Local Diagnostic Reference Levels for Mammography in Dubai},
journal = {Diagnostics},
year = {2023},
volume = {14},
number = {1},
pages = {8},
doi = {10.3390/diagnostics14010008}
}