EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Establishment of Local Diagnostic Reference Levels for Head CT Imaging in the Madina Region, Saudi Arabia

Sultan F Alhujaili, Abdulaziz S Alshabibi, Feras Alafer, Ziyad Alrowaili iD, Hasan Salah iD, Abdelmoneim Sulieman, Mahmoud Subahi, Khaled Al-Raddadi, Mohamed Abuzaid iD

Diagnostics · 21.12.2024 · 14 (24) · 2882

DOI: 10.3390/diagnostics14242882 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 21.12.2024. Verfasst von Sultan F Alhujaili und 8 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Sciences and Medical Imaging Department, College of Applied Medical Sciences, Jouf University, Sakaka 72388, Saudi Arabia. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Computed Tomography (CT) is crucial in medical diagnosis, particularly for head examinations. Diagnostic Reference Levels (DRLs) are pivotal in balancing diagnostic efficacy with radiation safety. International organizations such as the International Atomic Energy Agency (IAEA) and the International Commission on Radiological Protection (ICRP) provide guidelines for establishing DRLs, emphasizing their importance in optimizing radiation doses.

Aim

This study aimed to establish and standardize DRLs for head CT imaging in institutional and regional settings, emphasizing the need for tailored reference levels specific to each region’s practices and standards.

Method

Data collection included patient demographics, imaging parameters, and radiation dose indices, namely volume-weighted CT dose index (CTDIvol) and dose-length product (DLP). Statistical analyses were conducted to determine the median and 3rd quartile values for establishing DRLs. The results were compared with national and international benchmarks to assess variations in radiation doses across regions.

Results

Demographic profiles detailed gender distributions and ages across hospitals. Imaging parameters exhibited variability in tube voltage, milliampere-seconds (mAs), pitch, scan length, and field of view (FOV). For CTDIvol, the 3rd quartile value was 65.8 mGy (range: 24.8–85.9 mGy), and for DLP, it was 1230.95 mGy·cm (range: 382.3–1189.0 mGy·cm). These values were slightly higher than the national DRLs for Saudi Arabia in 2021 and other international benchmarks, underscoring the need for further optimization and alignment of protocols.

Conclusion

Optimizing and standardizing DRLs for head CT imaging is crucial for effectively managing radiation doses while ensuring diagnostic accuracy. Comparison with national and international benchmarks highlighted the importance of tailoring reference levels to regional practices and standards, ensuring patient safety without compromising diagnostic efficacy.

Schlagwörter

Stichwörter der Autor:innen

Saudi Arabiacomputed tomographydiagnostic reference levelshead CTradiation exposure

Autor:innen und Institutionen

  • Radiation Sciences and Medical Imaging Department, College of Applied Medical Sciences, Jouf University, Sakaka 72388, Saudi Arabia.
  • Department of Radiological Sciences, The College of Applied Medical Sciences, King Saud University, Riyadh 12372, Saudi Arabia.
  • Physics Department, College of Science, Jouf University, P.O. Box 2014, Sakaka 72388, Saudi Arabia.
  • Nuclear Medicine Department, Inaya Medical College, Riyadh 13541, Saudi Arabia.
  • Radiology Sciences Department, College of Applied Medical Sciences, King Saud Bin Abdulaziz University Health Sciences, P.O. Box 2477, Al-Ahsa 31982, Saudi Arabia.
  • Department of Radiology, King Salman Medical City, Ministry of Health, Madina 42319, Saudi Arabia.

ORCID-Profile: Ziyad Alrowaili, Hasan Salah, Mohamed Abuzaid

Zitieren

APA

Alhujaili, S. F., Alshabibi, A. S., Alafer, F., Alrowaili, Z., Salah, H., Sulieman, A., Subahi, M., Al-Raddadi, K., & Abuzaid, M. (2024). Establishment of Local Diagnostic Reference Levels for Head CT Imaging in the Madina Region, Saudi Arabia. Diagnostics, 14(24), 2882. https://doi.org/10.3390/diagnostics14242882

Vancouver

Alhujaili SF, Alshabibi AS, Alafer F, Alrowaili Z, Salah H, Sulieman A, et al. Establishment of Local Diagnostic Reference Levels for Head CT Imaging in the Madina Region, Saudi Arabia. Diagnostics. 2024;14(24):2882. doi:10.3390/diagnostics14242882

BibTeX
@article{Alhujaili2024,
  author = {Alhujaili, Sultan F and Alshabibi, Abdulaziz S and Alafer, Feras and Alrowaili, Ziyad and Salah, Hasan and Sulieman, Abdelmoneim and Subahi, Mahmoud and Al-Raddadi, Khaled and Abuzaid, Mohamed},
  title = {Establishment of Local Diagnostic Reference Levels for Head CT Imaging in the Madina Region, Saudi Arabia},
  journal = {Diagnostics},
  year = {2024},
  volume = {14},
  number = {24},
  pages = {2882},
  doi = {10.3390/diagnostics14242882}
}
Kostenlos starten →