Deep-Learning-Based Reconstruction of Single-Breath-Hold 3 mm HASTE Improves Abdominal Image Quality and Reduces Acquisition Time: A Quantitative Analysis
Current Oncology · 2025
DOI: 10.3390/curroncol32010030 ↗Kurz gefasst
Fachartikel in der Zeitschrift Current Oncology, 2025. Verfasst von Felix Kubicka und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Charité-Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health,…. Hauptthemen laut MEDLINE: Deep Learning, Breath Holding, Magnetic Resonance Imaging, Abdomen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: German Research Foundation, Siemens Healthcare (Erlangen, Bavara, Germany).
Abstract (Originalsprache)
Purpose
Breath-hold T2-weighted half-Fourier acquisition single-shot turbo spin echo (HASTE) magnetic resonance imaging (MRI) of the upper abdomen with a slice thickness below 5 mm suffers from high image noise and blurring. The purpose of this prospective study was to improve image quality and accelerate imaging acquisition by using single-breath-hold T2-weighted HASTE with deep learning (DL) reconstruction (DL-HASTE) with a 3 mm slice thickness.
Method
MRI of the upper abdomen with DL-HASTE was performed in 35 participants (5 healthy volunteers and 30 patients) at 3 Tesla. In a subgroup of five healthy participants, signal-to-noise ratio (SNR) analysis was used after DL reconstruction to identify the smallest possible layer thickness (1, 2, 3, 4, 5 mm). DL-HASTE was acquired with a 3 mm slice thickness (DL-HASTE-3 mm) in 30 patients and compared with 5 mm DL-HASTE (DL-HASTE-5 mm) and with standard HASTE (standard-HASTE-5 mm). Image quality and motion artifacts were assessed quantitatively using Laplacian variance and semi-quantitatively by two radiologists using five-point Likert scales.
Results
In the five healthy participants, DL-HASTE-3 mm was identified as the optimal slice (SNR 23.227 ± 3.901). Both DL-HASTE-3 mm and DL-HASTE-5 mm were assigned significantly higher overall image quality scores than standard-HASTE-5 mm (Laplacian variance, both p < 0.001; Likert scale, p < 0.001). Compared with DL-HASTE-5 mm (1.10 × 10−5 ± 6.93 × 10−6), DL-HASTE-3 mm (1.56 × 10−5 ± 8.69 × 10−6) provided a significantly higher SNR Laplacian variance (p < 0.001) and sharpness sub-scores for the intestinal tract, adrenal glands, and small anatomic structures (bile ducts, pancreatic ducts, and vessels; p < 0.05). Lesion detectability was rated excellent for both DL-HASTE-3 mm and DL-HASTE-5 mm (both: 5 [IQR4–5]) and was assigned higher scores than standard-HASTE-5 mm (4 [IQR4–5]; p < 0.001). DL-HASTE reduced the acquisition time by 63–69% compared with standard-HASTE-5 mm (p < 0.001).
Conclusions
DL-HASTE is a robust abdominal MRI technique that improves image quality while at the same time reducing acquisition time compared with the routine clinical HASTE sequence. Using ultra-thin DL-HASTE-3 mm results in an even greater improvement with a similar SNR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Charité-Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Charitéplatz 1, 10117 Berlin, Germany.
- MR Applications Predevelopment, Siemens Healthcare GmbH, Allee am Roethelheimpark 2, 91052 Erlangen, Germany.
ORCID-Profile: Felix Kubicka, Tom Meyer, Dominik Nickel, Elisabeth Weiland, Moritz Wagner, Stephan Rodrigo Marticorena Garcia
Förderung
- German Research Foundation
- Siemens Healthcare (Erlangen, Bavara, Germany)
Zitieren
APA
Kubicka, F., Tan, Q., Meyer, T., Nickel, D., Weiland, E., Wagner, M., & Marticorena Garcia, S. R. (2025). Deep-Learning-Based Reconstruction of Single-Breath-Hold 3 mm HASTE Improves Abdominal Image Quality and Reduces Acquisition Time: A Quantitative Analysis. Current Oncology. https://doi.org/10.3390/curroncol32010030
Vancouver
Kubicka F, Tan Q, Meyer T, Nickel D, Weiland E, Wagner M, et al. Deep-Learning-Based Reconstruction of Single-Breath-Hold 3 mm HASTE Improves Abdominal Image Quality and Reduces Acquisition Time: A Quantitative Analysis. Current Oncology. 2025. doi:10.3390/curroncol32010030
BibTeX
@article{Kubicka2025,
author = {Kubicka, Felix and Tan, Qinxuan and Meyer, Tom and Nickel, Dominik and Weiland, Elisabeth and Wagner, Moritz and Marticorena Garcia, Stephan Rodrigo},
title = {Deep-Learning-Based Reconstruction of Single-Breath-Hold 3 mm HASTE Improves Abdominal Image Quality and Reduces Acquisition Time: A Quantitative Analysis},
journal = {Current Oncology},
year = {2025},
doi = {10.3390/curroncol32010030}
}
EUVIMED