EUVIMEDEUVIMED entdecken
Crossref

Deep Learning-Enhanced Single Breath-Hold Abdominal MRI at 0.55 T—Technical Feasibility and Image Quality Assessment

Alina Carolin Seifert, Hanns-Christian Breit, Markus M Obmann, Anastassia Korolenko, Marcel Dominik Nickel, Matthias Fenchel, Daniel T Boll, Jan Vosshenrich

Academic Radiology · 2025

DOI: 10.1016/j.acra.2025.08.013 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Academic Radiology, 2025. Verfasst von Alina Carolin Seifert und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University Hospital Basel, Basel, Switzerland (A.C.S., H.C.B., M.M.O., A.K., D.T.B., J.V.). Hauptthemen laut MEDLINE: Deep Learning, Breath Holding, Magnetic Resonance Imaging, Abdomen. Die Arbeit nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: Inherently lower signal-to-noise ratios hamper the broad clinical use of low-field abdominal MRI. This study aimed to investigate the technical feasibility and image quality of deep learning (DL)-enhanced T2 HASTE and T1 VIBE-Dixon abdominal MRI at 0.55 T. MATERIALS AND METHODS: From July 2024 to September 2024, healthy volunteers underwent conventional and DL-enhanced 0.55 T abdominal MRI, including conventional T2 HASTE, fat-suppressed T2 HASTE (HASTE FS), and T1 VIBE-Dixon acquisitions, and DL-enhanced single- (HASTE DLSBH) and multi-breath-hold HASTE (HASTE DLMBH), fat-suppressed single- (HASTE FS DLSBH) and multi-breath-hold HASTE (HASTE FS DLMBH), and T1 VIBE-Dixon (VIBE-DixonDL) acquisitions. Three abdominal radiologists evaluated the scans for quality parameters and artifacts (Likert scale 1-5), and incidental findings. Interreader agreement and comparative analyses were conducted. RESULTS: 33 healthy volunteers (mean age: 30±4years) were evaluated. Image quality was better for single breath-hold DL-enhanced MRI (all P 0.572). The number and size of incidental lesions were identical between techniques (16 lesions; mean diameter 8±5 mm; P=1.000). CONCLUSION: DL-based image reconstruction enables single breath-hold T2 HASTE and T1 VIBE-Dixon abdominal imaging at 0.55 T with better image quality than conventional MRI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningBreath HoldingMagnetic Resonance ImagingAbdomenImage Interpretation, Computer-AssistedImage EnhancementHumansFeasibility StudiesMaleAdultFemaleHealthy VolunteersSignal-To-Noise RatioArtifacts

Stichwörter der Autor:innen

AbdomenDeep learningHASTELow-field MRISingle breath-hold

Autor:innen und Institutionen

  • Department of Radiology, University Hospital Basel, Basel, Switzerland (A.C.S., H.C.B., M.M.O., A.K., D.T.B., J.V.).
  • Research & Clinical Translation, Magnetic Resonance, Siemens Healthineers AG, Erlangen, Germany (M.D.N., M.F.).
  • Department of Radiology, University Hospital Basel, Basel, Switzerland (A.C.S., H.C.B., M.M.O., A.K., D.T.B., J.V.). Electronic address: Jan.Vosshenrich@usb.ch.

Zitieren

APA

Seifert, A. C., Breit, H. C., Obmann, M. M., Korolenko, A., Nickel, M. D., Fenchel, M., Boll, D. T., & Vosshenrich, J. (2025). Deep Learning-Enhanced Single Breath-Hold Abdominal MRI at 0.55 T—Technical Feasibility and Image Quality Assessment. Academic Radiology. https://doi.org/10.1016/j.acra.2025.08.013

Vancouver

Seifert AC, Breit HC, Obmann MM, Korolenko A, Nickel MD, Fenchel M, et al. Deep Learning-Enhanced Single Breath-Hold Abdominal MRI at 0.55 T—Technical Feasibility and Image Quality Assessment. Academic Radiology. 2025. doi:10.1016/j.acra.2025.08.013

BibTeX
@article{Seifert2025,
  author = {Seifert, Alina Carolin and Breit, Hanns-Christian and Obmann, Markus M and Korolenko, Anastassia and Nickel, Marcel Dominik and Fenchel, Matthias and Boll, Daniel T and Vosshenrich, Jan},
  title = {Deep Learning-Enhanced Single Breath-Hold Abdominal MRI at 0.55 T—Technical Feasibility and Image Quality Assessment},
  journal = {Academic Radiology},
  year = {2025},
  doi = {10.1016/j.acra.2025.08.013}
}
Kostenlos starten →