EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dynamic Response of Transmission Tower-Line Systems Due to Ground Vibration Caused by High-Speed Trains

Guifeng Zhao, Meng Wang, Ying Liu, Meng Zhang

Buildings · 18.11.2023 · 13 (11) · 2884

DOI: 10.3390/buildings13112884 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 18.11.2023. Verfasst von Guifeng Zhao und 3 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Henan, Cultivating Fund Project for Young Teachers of Zhengzhou University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the continuous expansion of the scale of power grid and transportation infrastructure construction, the number of crossovers between transmission lines and high-speed railways continues to increase. At present, there is a lack of systematic research on the dynamic characteristics of transmission tower-line structures crossing high-speed railways under vehicle-induced ground vibration. This article focuses on the phenomenon of accidents such as line drops when crossing areas in recent years and establishes a high-speed train track foundation soil finite element model in ABAQUS that considers track irregularity. The three-dimensional vibration characteristics and attenuation law of train ground vibration are analyzed. Acceleration data for key points are also extracted. A separate finite element model of the transmission tower-line system is established in ANSYS, where acceleration is applied as an excitation to the transmission tower-line system, and the coupling effect between the tower and the line is considered to analyze its dynamic response. Subsequently, modal analysis is conducted on the tower-line system, providing the vibration modes and natural frequencies of the transmission tower-line structure. The effects of factors such as train speed, soil quality, and distance from the tower to the track on the dynamic response of the transmission tower-line system under vehicle-induced ground vibration are studied. The results show that the speed range (300 km/h–400 km/h) and track distance range (4.5 m–30 m) with the greatest impacts are obtained. The research results can provide a reference for the reasonable design of transmission tower-line systems in high-speed railway sections.

Förderung

  • Natural Science Foundation of Henan
  • Cultivating Fund Project for Young Teachers of Zhengzhou University

Zitieren

APA

Zhao, G., Wang, M., Liu, Y., & Zhang, M. (2023). Dynamic Response of Transmission Tower-Line Systems Due to Ground Vibration Caused by High-Speed Trains. Buildings, 13(11), 2884. https://doi.org/10.3390/buildings13112884

Vancouver

Zhao G, Wang M, Liu Y, Zhang M. Dynamic Response of Transmission Tower-Line Systems Due to Ground Vibration Caused by High-Speed Trains. Buildings. 2023;13(11):2884. doi:10.3390/buildings13112884

BibTeX
@article{Zhao2023,
  author = {Zhao, Guifeng and Wang, Meng and Liu, Ying and Zhang, Meng},
  title = {Dynamic Response of Transmission Tower-Line Systems Due to Ground Vibration Caused by High-Speed Trains},
  journal = {Buildings},
  year = {2023},
  volume = {13},
  number = {11},
  pages = {2884},
  doi = {10.3390/buildings13112884}
}