EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Extreme-Value Combination Rules for Tower–Line Systems Under Non-Gaussian Wind-Induced Vibration Response

Shuang Zhao, Xianhong Zhang, Chentao Zhang, Zhitao Yan, Xueqin Zhang, Bin Zhang, Xianxing Dai

Buildings · 29.05.2025 · 15 (11) · 1871

DOI: 10.3390/buildings15111871 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 29.05.2025. Verfasst von Shuang Zhao und 6 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Postdoctoral Science Foundation, Special Funding of Chongqing Postdoctoral Research Project, Natural Science Foundation of Chongqing Municipal Science and Technology Commission.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Currently, extreme response analysis of tower–line systems typically assumes each component response follows a stationary Gaussian process. However, actual structural responses often exhibit significant non-Gaussian characteristics, potentially compromising structural safety during service life. Based on the first-passage theory and the complete quadratic combination (CQC) rule, this study investigates the extreme-value combination of non-Gaussian wind-induced responses for tower–line systems. Subsequently, wind tunnel test data are utilized to generate extreme-value samples with specified first four statistical moments through Monte Carlo simulation. An extensive parametric study was conducted to investigate the influence of non-Gaussian response components on combined extreme responses, leading to the development of a modified CQC (MCQC) rule for extreme-value estimation. Quantitative analyses incorporating both correlation coefficients and standard deviations demonstrated that among the classical combination rules, the proposed MCQC rule provides superior accuracy in estimating the total wind-induced response of tower–line systems. The validity of the MCQC rule was subsequently verified through wind tunnel test data, with the results showing excellent agreement between predicted and experimental values. The research results provide some reference for strengthening the wind resistance toughness of tower–line systems under wind load.

Förderung

  • China Postdoctoral Science Foundation
  • Special Funding of Chongqing Postdoctoral Research Project
  • Natural Science Foundation of Chongqing Municipal Science and Technology Commission
  • Chongqing Construction Science and Technology Plan Project
  • Scientific Research Project of Chongqing Design Group Co. Ltd
  • Open Research Project of the University Enterprise Collaborative Innovation Center of Chongqing University of Science & Technology
  • Gansu Provincial Science and Technology Plan

Zitieren

APA

Zhao, S., Zhang, X., Zhang, C., Yan, Z., Zhang, X., Zhang, B., & Dai, X. (2025). Extreme-Value Combination Rules for Tower–Line Systems Under Non-Gaussian Wind-Induced Vibration Response. Buildings, 15(11), 1871. https://doi.org/10.3390/buildings15111871

Vancouver

Zhao S, Zhang X, Zhang C, Yan Z, Zhang X, Zhang B, et al. Extreme-Value Combination Rules for Tower–Line Systems Under Non-Gaussian Wind-Induced Vibration Response. Buildings. 2025;15(11):1871. doi:10.3390/buildings15111871

BibTeX
@article{Zhao2025,
  author = {Zhao, Shuang and Zhang, Xianhong and Zhang, Chentao and Yan, Zhitao and Zhang, Xueqin and Zhang, Bin and Dai, Xianxing},
  title = {Extreme-Value Combination Rules for Tower–Line Systems Under Non-Gaussian Wind-Induced Vibration Response},
  journal = {Buildings},
  year = {2025},
  volume = {15},
  number = {11},
  pages = {1871},
  doi = {10.3390/buildings15111871}
}
Kostenlos starten →