EUVIMEDEUVIMED entdecken
Crossref

Beyond Orthogonal Wind Loading: Direction-Sensitive Flexural–Torsional Response of Transmission Tower–Line Systems

F. B. Chen, Z. Q. Gu, Y. C. Chen, X. Kuang, C. Q. Yu, Y. Li, Z. R. Shu

International Journal of Structural Stability and Dynamics · 06.11.2026

DOI: 10.1142/s0219455428500563 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Structural Stability and Dynamics, online erschienen am 06.11.2026. Verfasst von F. B. Chen und 6 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transmission towers are conventionally designed for orthogonal wind directions, although skew winds may induce flexural–torsional coupling that is poorly represented in current design practice. This study investigates wind-induced responses of a transmission tower–line system over wind attack angles of [Formula: see text]–[Formula: see text]. A [Formula: see text] angular increment is applied within critical ranges, and the torsional contribution to member stress is quantified through stress decomposition. Skew winds generate a pronounced M-shaped, double-peaked distribution of dynamic unbalanced tension at conductor attachment points. Wind directions of [Formula: see text] and [Formula: see text] emerge as critical cases for torsional vibration. At [Formula: see text], the peak dynamic tension difference reaches 10.83[Formula: see text]kN and the relative torsional angle reaches [Formula: see text][Formula: see text]rad, approximately 75 times the value under orthogonal wind. Structural responses also vary sharply over [Formula: see text]–[Formula: see text] and [Formula: see text]–[Formula: see text], demonstrating strong sensitivity to small directional changes. Under the most adverse [Formula: see text] case, torsion induced by the unbalanced tension contributes 15.6% of the total member stress. These findings highlighted the skew wind–dynamic tension imbalance–torsional response mechanism and demonstrate that neglecting skew-wind-induced torsion may lead to unconservative transmission-tower design.

Zitieren

APA

Chen, F. B., Gu, Z. Q., Chen, Y. C., Kuang, X., Yu, C. Q., Li, Y., & Shu, Z. R. (2026). Beyond Orthogonal Wind Loading: Direction-Sensitive Flexural–Torsional Response of Transmission Tower–Line Systems. International Journal of Structural Stability and Dynamics. https://doi.org/10.1142/s0219455428500563

Vancouver

Chen FB, Gu ZQ, Chen YC, Kuang X, Yu CQ, Li Y, et al. Beyond Orthogonal Wind Loading: Direction-Sensitive Flexural–Torsional Response of Transmission Tower–Line Systems. International Journal of Structural Stability and Dynamics. 2026. doi:10.1142/s0219455428500563

BibTeX
@article{Chen2026,
  author = {Chen, F. B. and Gu, Z. Q. and Chen, Y. C. and Kuang, X. and Yu, C. Q. and Li, Y. and Shu, Z. R.},
  title = {Beyond Orthogonal Wind Loading: Direction-Sensitive Flexural–Torsional Response of Transmission Tower–Line Systems},
  journal = {International Journal of Structural Stability and Dynamics},
  year = {2026},
  doi = {10.1142/s0219455428500563}
}
Kostenlos starten →