Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Dalia N Elsheakh und 2 weiteren Autor:innen. Beteiligte Einrichtung: Electrical Department, Faculty of Engineering and Technology, Badr University in Cairo, Badr 11829, Egypt. Hauptthemen laut MEDLINE: Biosensing Techniques, Blood Glucose, Blood Glucose Self-Monitoring. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper introduces a novel-shaped, compact, multiband monopole antenna sensor incorporating an irregular curved split-ring resonator (SRR) design for non-invasive, continuous monitoring of human blood glucose levels (BGL). The sensor operates at multiple resonance frequencies: 0.94, 1.5, 3, 4.6, and 6.3 GHz, achieving coefficient reflection impedance bandwidths ≤ −10 dB of 4%, 1%, 3.5%, 65%, and 50%, respectively. Additionally, novel shapes of two SRR metamaterial cells create notches at 1.7 GHz and 4.4 GHz. The antenna is fabricated on an economical FR4 substrate with compact dimensions of 35 × 50 × 1.6 mm3. The sensor’s performance is evaluated using 3D electromagnetic software, incorporating a human finger phantom model and applying the Cole–Cole model to mimic the blood layer’s sensitivity to blood glucose variations. The phantom model is positioned at different angles relative to the biosensor to detect frequency shifts corresponding to different glucose levels. Experimental validation involves placing a real human finger around the sensor to measure resonant frequency, magnitude, and phase changes. The fabricated sensor demonstrates a superior sensitivity of 24 MHz/mg/dL effectiveness compared to existing methods. This emphasizes its potential for practical, non-invasive glucose monitoring applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesBlood GlucoseBlood Glucose Self-MonitoringHumansEquipment Design

Stichwörter der Autor:innen

continuous monitoringglucose levelsmonopole antennamultiband and sensornon-invasivesplit-ring resonator (SRR)

Substanzen

Blood Glucose

Autor:innen und Institutionen

  • Electrical Department, Faculty of Engineering and Technology, Badr University in Cairo, Badr 11829, Egypt.
  • Microstrip Department, Electronics Research Institute (ERI), El Nozha 11843, Egypt.
  • Electronics and Communications Engineering Department, Faculty of Engineering, Ain Shams University, Cairo 11517, Egypt.

ORCID-Profile: Dalia N Elsheakh, Angie R Eldamak

Zitieren

APA

Elsheakh, D. N., Mohamed, E. H., & Eldamak, A. R. (2025). Blood Glucose Monitoring Biosensor Based on Multiband Split-Ring Resonator Monopole Antenna. Biosensors. https://doi.org/10.3390/bios15040250

Vancouver

Elsheakh DN, Mohamed EH, Eldamak AR. Blood Glucose Monitoring Biosensor Based on Multiband Split-Ring Resonator Monopole Antenna. Biosensors. 2025. doi:10.3390/bios15040250

BibTeX
@article{Elsheakh2025,
  author = {Elsheakh, Dalia N and Mohamed, El-Hawary and Eldamak, Angie R},
  title = {Blood Glucose Monitoring Biosensor Based on Multiband Split-Ring Resonator Monopole Antenna},
  journal = {Biosensors},
  year = {2025},
  doi = {10.3390/bios15040250}
}
Kostenlos starten →