EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Construction of Metal–Organic Framework as a Novel Platform for Ratiometric Determination of Cyanide

Zongbao Sun, Zhiwei Wu, Yiran Zong, Chen Li, Wang Guo, Yiqing Guo, Xiaobo Zou

Biosensors · 27.05.2024 · 14 (6) · 276

DOI: 10.3390/bios14060276 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 27.05.2024. Verfasst von Zongbao Sun und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China. Hauptthemen laut MEDLINE: Cyanides, Metal-Organic Frameworks, Electrochemical Techniques, Limit of Detection. Die Arbeit wurde bisher 15-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jiangsu Province, Key Research and Development Program of Jiangsu Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Metal–organic frameworks (MOFs) are frequently utilized as sensing materials. Unfortunately, the low conductivity of MOFs hinder their further application in electrochemical determination. To overcome this limitation, a novel modification strategy for MOFs was proposed, establishing an electrochemical determination method for cyanides in Baijiu. Co and Ni were synergistically used as the metal active centers, with meso−Tetra(4−carboxyphenyl)porphine (TCPP) and Ferrocenecarboxylic acid (Fc−COOH) serving as the main ligands, synthesizing Ni/Co−MOF−TCPP−Fc through a hydrothermal method. The prepared MOF exhibited improved conductivity and stable ratio signals, enabling rapid and sensitive determination of cyanides. The screen−printed carbon electrodes (SPCE) were suitable for in situ and real−time determination of cyanide by electrochemical sensors due to their portability, low cost, and ease of mass production. A logarithmic linear response in the range of 0.196~44 ng/mL was demonstrated by this method, and the limit of detection (LOD) was 0.052 ng/mL. Compared with other methods, the sensor was constructed by a one−step synthesis method, which greatly simplifies the analysis process, and the determination time required was only 4 min. During natural cyanide determinations, recommended readouts match well with GC−MS with less than 5.9% relative error. Moreover, this electrochemical sensor presented a promising method for assessing the safety of cyanides in Baijiu.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CyanidesMetal-Organic FrameworksElectrochemical TechniquesLimit of DetectionElectrodesBiosensing TechniquesNickelFerrous CompoundsMetallocenesCobalt

Stichwörter der Autor:innen

Fc−COOHMOFTCPPcyanideelectrochemical sensor

Substanzen

CyanidesMetal-Organic FrameworksNickelFerrous CompoundsMetallocenesCobaltferrocenecarboxylic acid

Autor:innen und Institutionen

  • School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China.

Förderung

  • Jiangsu Province
  • Key Research and Development Program of Jiangsu Province

Zitieren

APA

Sun, Z., Wu, Z., Zong, Y., Li, C., Guo, W., Guo, Y., & Zou, X. (2024). Construction of Metal–Organic Framework as a Novel Platform for Ratiometric Determination of Cyanide. Biosensors, 14(6), 276. https://doi.org/10.3390/bios14060276

Vancouver

Sun Z, Wu Z, Zong Y, Li C, Guo W, Guo Y, et al. Construction of Metal–Organic Framework as a Novel Platform for Ratiometric Determination of Cyanide. Biosensors. 2024;14(6):276. doi:10.3390/bios14060276

BibTeX
@article{Sun2024,
  author = {Sun, Zongbao and Wu, Zhiwei and Zong, Yiran and Li, Chen and Guo, Wang and Guo, Yiqing and Zou, Xiaobo},
  title = {Construction of Metal–Organic Framework as a Novel Platform for Ratiometric Determination of Cyanide},
  journal = {Biosensors},
  year = {2024},
  volume = {14},
  number = {6},
  pages = {276},
  doi = {10.3390/bios14060276}
}
Kostenlos starten →