EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Laser-Induced Graphene Decorated with MOF-Derived NiCo-LDH for Highly Sensitive Non-Enzymatic Glucose Sensor

Longxiao Li, Yufei Han, Yuzhe Zhang, Weijia Wu, Wei Du, Guojun Wen, Siyi Cheng

Molecules · 29.11.2024 · 29 (23) · 5662

DOI: 10.3390/molecules29235662 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, online erschienen am 29.11.2024. Verfasst von Longxiao Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering and Electronic Information, China University of Geosciences, Wuhan 430074, China. Hauptthemen laut MEDLINE: Graphite, Glucose, Biosensing Techniques, Lasers. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Hubei Province, Natural Science Foundation of Chongqing.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Designing and fabricating a highly sensitive non-enzymatic glucose sensor is crucial for the early detection and management of diabetes. Meanwhile, the development of innovative electrode substrates has become a key focus for addressing the growing demand for constructing flexible sensors. Here, a simple one-step laser engraving method is applied for preparing laser-induced graphene (LIG) on polyimide (PI) film, which serves as the sensor substrate. NiCo-layered double hydroxides (NiCo-LDH) are synthesized on LIG as a precursor, utilizing the zeolitic imidazolate framework (ZIF-67), and then reacted with Ni(NO3)2 via solvent-thermal methods. The sensitivity of the non-enzymatic electrochemical glucose sensor is significantly improved by employing NiCo-LDH/LIG as the sensing material. The porous and interconnected structure of NiCo-LDH, derived from ZIF-67, enhances the accessibility of electrochemically active sites, while the incorporation of LIG ensures exceptional conductivity. The combination of NiCo-LDH with LIG enables efficient electron transport, leading to an increased electrochemically active surface area and enhanced catalytic efficiency. The fabricated electrode achieves a low glucose detection limit of 0.437 μM and demonstrates a high sensitivity of 1141.2 and 631.1 μA mM−2 cm−2 within the linear ranges of 0–770 μM and 770–1970 μM, respectively. Furthermore, the NiCo-LDH/LIG glucose sensor demonstrates superior reliability and little impact from other substances. A flexible integrated LIG-based non-enzymatic glucose sensor has been developed, demonstrating high sensitivity and suggesting a promising application for LIG-based chemical sensors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteGlucoseBiosensing TechniquesLasersElectrochemical TechniquesHydroxidesMetal-Organic FrameworksElectrodesNickelLimit of Detection

Stichwörter der Autor:innen

NiCo-LDHZIF-67flexibleglucose sensorlaser-induced graphene

Substanzen

GraphiteGlucoseHydroxidesMetal-Organic FrameworksNickel

Autor:innen und Institutionen

  • School of Mechanical Engineering and Electronic Information, China University of Geosciences, Wuhan 430074, China.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Hubei Province
  • Natural Science Foundation of Chongqing
  • Key research and development project of Hubei Province

Zitieren

APA

Li, L., Han, Y., Zhang, Y., Wu, W., Du, W., Wen, G., & Cheng, S. (2024). Laser-Induced Graphene Decorated with MOF-Derived NiCo-LDH for Highly Sensitive Non-Enzymatic Glucose Sensor. Molecules, 29(23), 5662. https://doi.org/10.3390/molecules29235662

Vancouver

Li L, Han Y, Zhang Y, Wu W, Du W, Wen G, et al. Laser-Induced Graphene Decorated with MOF-Derived NiCo-LDH for Highly Sensitive Non-Enzymatic Glucose Sensor. Molecules. 2024;29(23):5662. doi:10.3390/molecules29235662

BibTeX
@article{Li2024,
  author = {Li, Longxiao and Han, Yufei and Zhang, Yuzhe and Wu, Weijia and Du, Wei and Wen, Guojun and Cheng, Siyi},
  title = {Laser-Induced Graphene Decorated with MOF-Derived NiCo-LDH for Highly Sensitive Non-Enzymatic Glucose Sensor},
  journal = {Molecules},
  year = {2024},
  volume = {29},
  number = {23},
  pages = {5662},
  doi = {10.3390/molecules29235662}
}
Kostenlos starten →