“Near-zero background signal” sensing platform for tumor marker based on catalytic amplification strategy in chronocoulometry
Talanta · 2026
DOI: 10.1016/j.talanta.2026.129352 ↗Kurz gefasst
Fachartikel in der Zeitschrift Talanta, 2026. Verfasst von Ziwei Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Capital Normal University, Beijing, 100048, China. Hauptthemen laut MEDLINE: Biomarkers, Tumor, Electrochemical Techniques, Biosensing Techniques, Prostate-Specific Antigen. Die Arbeit nennt 50 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
In practical applications, the long-term stability of electrochemical (EC) sensors during continuous monitoring of target substances is particularly critical. However, due to complex detection environments that readily cause background signal interference, achieving long-term stability and high-sensitivity detection still faces significant challenges. To solve this issue, a "near-zero background signal" approach was designed via a catalytic amplification strategy in chronocoulometry, constructing a sensitive and stable tumor marker sensing platform. Specifically, glucose oxidase (GOx) was encapsulated within the covalent organic frameworks (COFs) during the synthetic process of gold nanoparticles (AuNPs)/GOx@COFs. Subsequently, an environmentally tolerant immunoprobe was successfully prepared by conjugating AuNPs/GOx@COFs with antibodies. The surface of electrodes modified with AuNPs/multi-walled carbon nanotubes immobilized a large amount of the electroactive material ferrocene (Fc), achieving the first catalytic amplification of EC signals. Following the construction of the immunosandwich sensing interface on the electrode surface, glucose was catalyzed by GOx to generate hydrogen peroxide (H2O2), and Fc+/Fc catalyzed the decomposition of H2O2, enabling the second amplification of the EC signal. As a proof of concept, prostate-specific antigen (PSA) was selected as a model analyte for verification. The sensing interface demonstrated highly sensitive detection with a low limit of detection (LOD) of 11.96 fg mL-1 and maintained stability for up to 6 weeks (signal deviation rate of -2.48 %). This strategy effectively enhances EC signal response and exhibits stability, providing a universal and feasible concept for the precise, sensitive, and stable detection of tumor markers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Capital Normal University, Beijing, 100048, China.
- Clinical Laboratory Departmen, The Affiliated Hospital of Liaoning University of Traditional Chinese Medicine, Shenyang, 110000, China.
- Department of Chemistry, Capital Normal University, Beijing, 100048, China. Electronic address: hanhongliang@cnu.edu.cn.
- Department of Chemistry, Capital Normal University, Beijing, 100048, China. Electronic address: mazhanfang@cnu.edu.cn.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Wang, Z., Zhang, S., Song, G., Han, H., & Ma, Z. (2026). “Near-zero background signal” sensing platform for tumor marker based on catalytic amplification strategy in chronocoulometry. Talanta. https://doi.org/10.1016/j.talanta.2026.129352
Vancouver
Wang Z, Zhang S, Song G, Han H, Ma Z. “Near-zero background signal” sensing platform for tumor marker based on catalytic amplification strategy in chronocoulometry. Talanta. 2026. doi:10.1016/j.talanta.2026.129352
BibTeX
@article{Wang2026,
author = {Wang, Ziwei and Zhang, Shuli and Song, Ge and Han, Hongliang and Ma, Zhanfang},
title = {“Near-zero background signal” sensing platform for tumor marker based on catalytic amplification strategy in chronocoulometry},
journal = {Talanta},
year = {2026},
doi = {10.1016/j.talanta.2026.129352}
}
EUVIMED