EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Detection of NT-proBNP Using Optical Fiber Back-Reflection Plasmonic Biosensors

Ana Sofia Assunção iD, Miguel Vidal iD, Maria João Martins, Ana Violeta Girão iD, Médéric Loyez iD, Christophe Caucheteur, José Mesquita-Bastos iD, Florinda M Costa iD, Sónia O Pereira iD, Cátia Leitão iD

Biosensors · 2024

DOI: 10.3390/bios14040173 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Ana Sofia Assunção und 9 weiteren Autor:innen. Beteiligte Einrichtung: i3N, Department of Physics, University of Aveiro, 3810-193 Aveiro, Portugal. Hauptthemen laut MEDLINE: Natriuretic Peptide, Brain, Biosensing Techniques, Peptide Fragments, Optical Fibers. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e Tecnologia, project i3N, project CICECO-Aveiro Institute of Materials.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Heart failure (HF) is a clinical entity included in cardiovascular diseases affecting millions of people worldwide, being a leading cause of hospitalization of older adults, and therefore imposing a substantial economic burden on healthcare systems. HF is characterized by dyspnea, fatigue, and edema associated with elevated blood levels of natriuretic peptides, such as N Terminal pro-B-type Natriuretic Peptide (NT-proBNP), for which there is a high demand for point of care testing (POCT) devices. Optical fiber (OF) biosensors offer a promising solution, capable of real-time detection, quantification, and monitoring of NT-proBNP concentrations in serum, saliva, or urine. In this study, immunosensors based on plasmonic uncladded OF tips were developed using OF with different core diameters (200 and 600 µm). The tips were characterized to bulk refractive index (RI), anddetection tests were conducted with NT-proBNP concentrations varying from 0.01 to 100 ng/mL. The 200 µm sensors showed an average total variation of 3.6 ± 2.5 mRIU, an average sensitivity of 50.5 mRIU/ng·mL−1, and a limit of detection (LOD) of 0.15 ng/mL, while the 600 µm sensors had a response of 6.1 ± 4.2 mRIU, a sensitivity of 102.8 mRIU/ng·mL−1, and an LOD of 0.11 ng/mL. Control tests were performed using interferents such as uric acid, glucose, and creatinine. The results show the potential of these sensors for their use in biological fluids.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Natriuretic Peptide, BrainBiosensing TechniquesPeptide FragmentsOptical FibersHumansHeart FailureLimit of Detection

Stichwörter der Autor:innen

N-terminal B-type natriuretic peptide (NT-proBNP)gold plasmonicsoptical fiber uncladded tip biosensorssurface plasmon resonance (SPR)

Substanzen

Natriuretic Peptide, Brainpro-brain natriuretic peptide (1-76)Peptide Fragments

Autor:innen und Institutionen

  • i3N, Department of Physics, University of Aveiro, 3810-193 Aveiro, Portugal.
  • CICECO-Aveiro Institute of Materials, Department of Materials and Ceramics Engineering, University of Aveiro, 3810-193 Aveiro, Portugal.
  • Electromagnetism and Telecommunication Department, University of Mons, 31 Bld Dolez, 7000 Mons, Belgium.
  • Institute of Biomedicine-iBiMED, School of Health Sciences, University of Aveiro, 3810-193 Aveiro, Portugal.

ORCID-Profile: Ana Sofia Assunção, Miguel Vidal, Ana Violeta Girão, Médéric Loyez, José Mesquita-Bastos, Florinda M Costa, Sónia O Pereira, Cátia Leitão

Förderung

  • Fundação para a Ciência e Tecnologia
  • project i3N
  • project CICECO-Aveiro Institute of Materials
  • FCT

Zitieren

APA

Assunção, A. S., Vidal, M., Martins, M. J., Girão, A. V., Loyez, M., Caucheteur, C., Mesquita-Bastos, J., Costa, F. M., Pereira, S. O., & Leitão, C. (2024). Detection of NT-proBNP Using Optical Fiber Back-Reflection Plasmonic Biosensors. Biosensors. https://doi.org/10.3390/bios14040173

Vancouver

Assunção AS, Vidal M, Martins MJ, Girão AV, Loyez M, Caucheteur C, et al. Detection of NT-proBNP Using Optical Fiber Back-Reflection Plasmonic Biosensors. Biosensors. 2024. doi:10.3390/bios14040173

BibTeX
@article{Assuno2024,
  author = {Assunção, Ana Sofia and Vidal, Miguel and Martins, Maria João and Girão, Ana Violeta and Loyez, Médéric and Caucheteur, Christophe and Mesquita-Bastos, José and Costa, Florinda M and Pereira, Sónia O and Leitão, Cátia},
  title = {Detection of NT-proBNP Using Optical Fiber Back-Reflection Plasmonic Biosensors},
  journal = {Biosensors},
  year = {2024},
  doi = {10.3390/bios14040173}
}
Kostenlos starten →