EUVIMEDEUVIMED entdecken
Crossref

Nanoencapsulated Optical Fiber-Based PEC Microelectrode: Highly Sensitive and Specific Detection of NT-proBNP and Its Implantable Performance

HuiYu Zou, Zhizhong Jiang, ErKang Bian, Jingjing Zhou, Shengqing Li, Yicheng Yang, HuiPing Guo, Yuancheng Liu, WuMing Wu, ChunYan Deng iD

Analytical Chemistry · 2025

DOI: 10.1021/acs.analchem.4c04757 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von HuiYu Zou und 9 weiteren Autor:innen. Beteiligte Einrichtung: Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University,…. Hauptthemen laut MEDLINE: Optical Fibers, Natriuretic Peptide, Brain, Peptide Fragments, Electrochemical Techniques. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 55 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microelectrodes offer exceptional sensitivity, rapid response, and versatility, making them ideal for real-time detection and monitoring applications. Photoelectrochemical (PEC) sensors have shown great value in many fields due to their high sensitivity, fast response, and ease of operation. Nevertheless, conventional PEC sensing relies on cumbersome external light sources and bulky electrodes, hindering its miniaturization and implantation, thereby limiting its application in real-time disease monitoring. To overcome these limitations, we developed a nanoencapsulated optical fiber (OF)-based PEC microelectrode. The microelectrode features TiO2/CdS nanocrystals and bis (2,2'-bipyridine) (10-methylphenanthroline [3,2-a:2'3'-c] pyridine ruthenium(II) dichloride ([Ru(bpy)2dppz]2+) @dsDNA/Au@epigallocatechin gallate nanoparticle (EGCG NP) layers. And its application for the detection of N-terminal pro-brain natriuretic peptide (NT-proBNP) as a biomarker of cardiovascular diseases was explored. An extensive linear range of 1-5000 pg mL-1 combined with a low detection limit of 0.36 pg mL-1 was achieved. This range covers not only the recommended threshold for excluding cardiovascular diseases in the clinical diagnosis of individuals across all age groups but also the prognostic target value. The sensor exhibited excellent selectivity and stability and notable labeling recovery capability in serum tests. Critically, the sensor successfully discriminated the alterations in NT-proBNP secretion levels within human smooth muscle cells, comparing pre- and poststimulation by platelet-derived growth factor-BB. Even more significantly, the skin puncture experiment conducted in mice demonstrated the remarkable implantability and biological compatibility of the OF-PEC microelectrode. This addresses critical challenges commonly faced by microelectrodes when used as implanted devices, such as minimizing invasive trauma, mitigating inflammation, and preventing biofouling, thereby firmly establishing their suitability for the development of advanced implantable sensing devices. Therefore, the present OF microelectrode PEC biosensor is not only cost-effective, easy to operate, and miniaturized but also holds significant potential for enabling more precise, more minimally invasive, and continuous monitoring of biological markers without causing inflammation. This capability is crucial for early disease detection, tracking disease progression, and facilitating personalized treatment strategies, which expands the practical application of PEC sensors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Optical FibersNatriuretic Peptide, BrainPeptide FragmentsElectrochemical TechniquesMicroelectrodesAnimalsMiceHumansLimit of Detection

Substanzen

Natriuretic Peptide, Brainpro-brain natriuretic peptide (1-76)Peptide Fragments

Autor:innen und Institutionen

  • Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.
  • School of Electronic Science and Engineering, Hunan Institute of Information Technology, Changsha, Hunan 410151, China.
  • Beijing Key Laboratory of Maternal-Fetal Medicine and Fetal Heart Disease & Echocardiography Department, Beijing Anzhen Hospital, Capital Medical University, Beijing 100069, China.
  • State Key Laboratory of Cardiovascular Disease, Fuwai HospitalRINGGOLD, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 102308, China.
  • Department of Dermatology, Xiangya Hospital, Central South University, Changsha 410078, China.

ORCID-Profile: ChunYan Deng

Zitieren

APA

Zou, H., Jiang, Z., Bian, E., Zhou, J., Li, S., Yang, Y., Guo, H., Liu, Y., Wu, W., & Deng, C. (2025). Nanoencapsulated Optical Fiber-Based PEC Microelectrode: Highly Sensitive and Specific Detection of NT-proBNP and Its Implantable Performance. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c04757

Vancouver

Zou H, Jiang Z, Bian E, Zhou J, Li S, Yang Y, et al. Nanoencapsulated Optical Fiber-Based PEC Microelectrode: Highly Sensitive and Specific Detection of NT-proBNP and Its Implantable Performance. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.4c04757

BibTeX
@article{Zou2025,
  author = {Zou, HuiYu and Jiang, Zhizhong and Bian, ErKang and Zhou, Jingjing and Li, Shengqing and Yang, Yicheng and Guo, HuiPing and Liu, Yuancheng and Wu, WuMing and Deng, ChunYan},
  title = {Nanoencapsulated Optical Fiber-Based PEC Microelectrode: Highly Sensitive and Specific Detection of NT-proBNP and Its Implantable Performance},
  journal = {Analytical Chemistry},
  year = {2025},
  doi = {10.1021/acs.analchem.4c04757}
}
Kostenlos starten →