Highly Stretchable and Robust Electrochemical Sensor Based on 3D Graphene Oxide–CNT Composite for Detecting Ammonium in Sweat
Biosensors · 21.03.2023 · 13 (3) · 409
DOI: 10.3390/bios13030409 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 21.03.2023. Verfasst von Yunzhi Hua und 6 weiteren Autor:innen. Beteiligte Einrichtung: Shenzhen Institute of Information Technology, Shenzhen 518172, China. Hauptthemen laut MEDLINE: Graphite, Nanotubes, Carbon, Ammonium Compounds. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: PhD Research Startup Project of Shenzhen Institute of Information Technology, High-Talent Research Funding under Grant, Project of Shenzhen Science and Technology Innovation Committee.
Abstract (Originalsprache)
Wearable electrochemical sensors have attracted tremendous attention and have been experiencing rapid growth in recent years. Sweat, one of the most suitable biological fluids for non-invasive monitoring, contains various chemical elements relating abundant information about human health conditions. In this work, a new type of non-invasive and highly stretchable potentiometric sweat sensor was developed based on all-solid-state ion-selective electrode (ISE) coupled with poly(dimethylsiloxane; PDMS) and polyurethane (PU). This highly stretchable composite of PDMS-PU allows the sensor to be robust, with the PDMS providing a flexible backbone and the PU enhancing the adhesion between the electrodes and the substrate. In addition, graphene–carbon nanotube (CNT) network 3D nanomaterials were introduced to modify the ion selective membrane (ISM) in order to increase the charge transfer activity of the ISEs, which also could minimize the formation of water layers on the electrode surface, as such nanomaterials are highly hydrophobic. As a result, the sensor demonstrated a wide detection range of NH4+ from 10−6 M to 10−1 M with high stability and sensitivity—showing a high sensitivity of 59.6 ± 1.5 mV/log [NH4+] and an LOD lower than 10−6 M. Under a strain of 40%, the sensor still showed a sensitivity of 42.7 ± 3.1 mV/log [NH4+]. The proposed highly stretchable and robust electrochemical sweat sensor provides a new choice for wearable-device-based personal daily healthcare management beyond hospital-centric healthcare monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Shenzhen Institute of Information Technology, Shenzhen 518172, China.
- Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen 518107, China.
- Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
- Shenzhen Key Laboratory of Photonic Devices and Sensing Systems for Internet of Things, Guangdong and Hong Kong Joint Research Centre for Optical Fiber Sensors, Shenzhen University, Shenzhen 518060, China.
Förderung
- PhD Research Startup Project of Shenzhen Institute of Information Technology
- High-Talent Research Funding under Grant
- Project of Shenzhen Science and Technology Innovation Committee
- Guangdong Basic and Applied Basic Research Foundation
- National Natural Science Foundation of China
- Science and Technology Innovation Commission of Shenzhen
- PhD Research Startup Project of the Shenzhen Institute of Information Technology
- High-Talent Research Funding
Zitieren
APA
Hua, Y., Guan, M., Xia, L., Chen, Y., Mai, J., Zhao, C., & Liao, C. (2023). Highly Stretchable and Robust Electrochemical Sensor Based on 3D Graphene Oxide–CNT Composite for Detecting Ammonium in Sweat. Biosensors, 13(3), 409. https://doi.org/10.3390/bios13030409
Vancouver
Hua Y, Guan M, Xia L, Chen Y, Mai J, Zhao C, et al. Highly Stretchable and Robust Electrochemical Sensor Based on 3D Graphene Oxide–CNT Composite for Detecting Ammonium in Sweat. Biosensors. 2023;13(3):409. doi:10.3390/bios13030409
BibTeX
@article{Hua2023,
author = {Hua, Yunzhi and Guan, Mingxiang and Xia, Linzhong and Chen, Yu and Mai, Junhao and Zhao, Cong and Liao, Changrui},
title = {Highly Stretchable and Robust Electrochemical Sensor Based on 3D Graphene Oxide–CNT Composite for Detecting Ammonium in Sweat},
journal = {Biosensors},
year = {2023},
volume = {13},
number = {3},
pages = {409},
doi = {10.3390/bios13030409}
}
EUVIMED