A Highly Stable Electrochemical Sensor Based on a Metal–Organic Framework/Reduced Graphene Oxide Composite for Monitoring the Ammonium in Sweat
Biosensors · 15.12.2024 · 14 (12) · 617
DOI: 10.3390/bios14120617 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 15.12.2024. Verfasst von Yunzhi Hua und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Information and Communication, Shenzhen Institute of Information Technology, Shenzhen 518172, China. Hauptthemen laut MEDLINE: Graphite, Sweat, Metal-Organic Frameworks, Electrochemical Techniques. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: PhD Research Startup Project of Shenzhen Institute of Information Technology, High-Talent Research Funding under Grant, National Natural Science Foundation of China (NSFC).
Abstract (Originalsprache)
The demand for non-invasive, real-time health monitoring has driven advancements in wearable sensors for tracking biomarkers in sweat. Ammonium ions (NH4+) in sweat serve as indicators of metabolic function, muscle fatigue, and kidney health. Although current ion-selective all-solid-state printed sensors based on nanocomposites typically exhibit good sensitivity (~50 mV/log [NH4+]), low detection limits (LOD ranging from 10−6 to 10−7 M), and wide linearity ranges (from 10−5 to 10−1 M), few have reported the stability test results necessary for their integration into commercial products for future practical applications. This study presents a highly stable, wearable electrochemical sensor based on a composite of metal–organic frameworks (MOFs) and reduced graphene oxide (rGO) for monitoring NH4+ in sweat. The synergistic properties of Ni-based MOFs and rGO enhance the sensor’s electrochemical performance by improving charge transfer rates and expanding the electroactive surface area. The MOF/rGO sensor demonstrates high sensitivity, with a Nernstian response of 59.2 ± 1.5 mV/log [NH4+], an LOD of 10−6.37 M, and a linearity range of 10−6 to 10−1 M. Additionally, the hydrophobic nature of the MOF/rGO composite prevents water layer formation at the sensing interface, thereby enhancing long-term stability, while its high double-layer capacitance minimizes potential drift (7.2 µV/s (i = ±1 nA)) in short-term measurements. Extensive testing verified the sensor’s exceptional stability, maintaining consistent performance and stable responses across varying NH4+ concentrations over 7 days under ambient conditions. On-body tests further confirmed the sensor’s suitability for the continuous monitoring of NH4+ levels during physical activities. Further investigations are required to fully elucidate the impact of interference from other sweat components (such as K+, Na+, Ca2+, etc.) and the influence of environmental factors (including the subject’s physical activity, posture, etc.). With a clearer understanding of these factors, the sensor has the potential to emerge as a promising tool for wearable health monitoring applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Information and Communication, Shenzhen Institute of Information Technology, Shenzhen 518172, China.
- Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen 518107, China.
- Key Laboratory of Clinical Evaluation Technology for Medical Device of Zhejiang Province, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310009, China.
- Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
- Shenzhen Key Laboratory of Photonic Devices and Sensing Systems for Internet of Things, Guangdong and Hong Kong Joint Research Centre for Optical Fiber Sensors, Shenzhen University, Shenzhen 518060, China.
ORCID-Profile: Yiping Wang
Förderung
- PhD Research Startup Project of Shenzhen Institute of Information Technology
- High-Talent Research Funding under Grant
- National Natural Science Foundation of China (NSFC)
- Zhejiang Provincial Natural Science Foundation of China
- Shenzhen Science and Technology Program
- High-Talent Research Funding
- Shenzhen Science and the Technology Program
Zitieren
APA
Hua, Y., Mai, J., Su, R., Ma, C., Liu, J., Zhao, C., Zhang, Q., Liao, C., & Wang, Y. (2024). A Highly Stable Electrochemical Sensor Based on a Metal–Organic Framework/Reduced Graphene Oxide Composite for Monitoring the Ammonium in Sweat. Biosensors, 14(12), 617. https://doi.org/10.3390/bios14120617
Vancouver
Hua Y, Mai J, Su R, Ma C, Liu J, Zhao C, et al. A Highly Stable Electrochemical Sensor Based on a Metal–Organic Framework/Reduced Graphene Oxide Composite for Monitoring the Ammonium in Sweat. Biosensors. 2024;14(12):617. doi:10.3390/bios14120617
BibTeX
@article{Hua2024,
author = {Hua, Yunzhi and Mai, Junhao and Su, Rourou and Ma, Chengwei and Liu, Jiayi and Zhao, Cong and Zhang, Qian and Liao, Changrui and Wang, Yiping},
title = {A Highly Stable Electrochemical Sensor Based on a Metal–Organic Framework/Reduced Graphene Oxide Composite for Monitoring the Ammonium in Sweat},
journal = {Biosensors},
year = {2024},
volume = {14},
number = {12},
pages = {617},
doi = {10.3390/bios14120617}
}